Boa tarde comunidade Yoreparo. Neste novo post, estou revisando um refrigerador MABE de 10 ou 12 pés com 2 portas horizontais que perderam todo o gás refrigerante 134-A, notando que ele possui uma válvula de serviço porque já havia sido...
Saudações a todos ... Continuando com um gabinete de geladeira Mabe modelo RMBZZ1 com duas portas verticais, o compressor é 1/5 e, de acordo com a tabela de especificações, a amperagem é de 2,2 no máximo, com 135 gramas de...
Hello friends of the Yoreparo community, I have a suzuki gn 2006 motorcycle which until yesterday, December 22, 2017, started without problems. today I decided to change the gas tank for another one that is more deteriorated, but in good...
Good morning to the entire community, according to the case already mentioned. Solve the entire plate and the one in the canyon. has been operating without problems for several days ... with this the issue is solved .. Thanks a...
Good afternoon colleagues in this opportunity I brought this case: I have a SAMSUNG CRT 21 inch TV model CT 5038 which turns on very well but after a while it turns off, I tap it on the housing and...
Best regards to all colleagues. On this occasion I had to replace a compressor of an executive refrigerator, its original compressor is 1/8 and I used a 1/6 used, clean with dielectric / electron, replace the filter drier, I emptied...
Good afternoon to everyone, and happy new year My case is the following I have an LG model MS microwave oven which has 2 diodes in the capacitor, one of them is damaged because it burns the input fuse, the...
Good afternoon colleagues and lovers of repairs on this new topic I have an ariston brand electric cooker or hob that the large burners do not heat very well, I have checked some components but still the same, the small...
Good afternoon to everyone again thanking God for the beautiful life he gives us every day .. On this occasion I have a problem with the compressor of my ares split 12000btu, the compressor began to sound very strong until...
Good evening colleagues here again looking for some help today is that at some point in the search I got a PDF with all the information of the magnetrons, their operation, the KVA configuration, among other things, a human error...
[size=120] Best regards to all of you continued with a case of an executive or bar-type fridge that arrived at [/size[=15.6pxrepa[[size=120] with the compressor damaged .. the following [/size] = 15.6pxaction = 15.6px: = 15.6px1) The compressor was replaced with...
[size=120] Greetings to all colleagues from Venezuela ... On this occasion I went to check a refrigerator LG BRAND MODEL GC-297WTQ two vertical doors with ice and water dispenser .. the case is as follows: the owner of the refrigerator...
Good afternoon colleagues, today it was to replace a compressor of 1/4 of an ETERNA refrigerator that on one side is conservative and the other freezer, both independent .. Note that the 0.034 2-meter long capillary tube is clogged and...
Hello colleagues, great greetings from Venezuela ... On this great opportunity I was presented with a family refrigerator with two horizontal doors that discarded the compressor. Noting the technical specifications of it I have found out that it is 1/5...
Good afternoon Yoreparo community. In this new post I am reviewing a 10 or 12 foot MABE refrigerator with 2 horizontal doors which lost all of the 134-A refrigerant gas, noticing that it has a service valve because it had...
Greetings to all ... Continuing with a case of a RMBZZ1 model Mabe refrigerator two vertical doors, the compressor is 1/5 and according to the specifications table the amperage is 2.2 maximum, with 135 grams of 134-A refrigerant, the which...
Saludos a todos colegas. Tengo un microondas Marca DAEWOO modelo KOR 63AM que desde hace días la hora se esta adelantando, al notar esto lo observe determinadamente y me di cuenta que por cada 30 SEGUNDOS cambia 1 MINUTO y...
[size=120]Saludos a todos de la comunidad. En este nuevo tema, quiero pedir ayuda con un split de 18000 BTU marca LG que usa refrigerante R22 y su consumo nominal es de 8.4 amp. Este equipo fue desintalado por alguien sin...
Gran saludos a la comunidad yoreparo. Nuevamente buscando soluciones en los que si saben del tema: estoy tratando de soldar tubos aluminio con cobre en un condensador de aire acondicionado de 5 ton. Estoy usando varilla de plata al 5%...
Saludos a todos..continuando con un caso de una nevera marca mabe modelo RM76ZBE1 dos puertas verticales, el compresor es de 1/5 y según la tabla de especificaciones el amperaje es de 2.2 máximo, con 135 gramos de refrigerante 134-A, el...