hace 6 años
hace 6 años
Greetings to all colleagues from Venezuela ... On this occasion I went to check a refrigerator LG BRAND MODEL GC-297WTQ two vertical doors with ice and water dispenser .. the case is as follows: the owner of the refrigerator I began to notice that every day it cooled less to the point that I stopped doing it, from there I started doing maintenance to the small condenser that has next to the compressor and to the fan, the fault continues, place the clamp meter and gave 1.0 AMPS, it seemed very strange because the size of the compressor is about 1/4 HP or 1/3, for some reason disconnect the fan from the small condenser and it began to cool or make ice in the evaporator, (already with the fan disconnected it generates CF error aware of the problem ) The amperage of consumption reached 1.2 AMPS, it kept working well, the filter drier at warm temperature, the discharge of the compressor very well, the condenser very well, after one hour, disconnect it p To put the fan back on and again the problem started already mentioned, I stop cooling in the evaporator .. the compressor has never been repaired so it has no service [/size[=15.6pxvvalve_size=120] to measure how many BAR has ... best regards to all
Mado
Mado
65
hace 6 años

Hello first click to know what price you have !!!! If you disconnect the condenser from the condenser and more or less in proliga, because it increases the price two things or the filter or the engine is clogged no longer yields and the consumption of a 1/4 or 1/3 motor is 1 amper or 1.5 maximum

Responder
ADMG2000
hace 6 años

Thank you for your help, making the necessary adjustments and then writing to you.

Responder
Mimol92
Mimol92
8.033
hace 6 años
hace 6 años
Good morning, first of all to make a good diagnosis, it is essential to measure the working pressure, as it is original you must use a pinch valve and with it you click the pipe and you get the reading of the operating pressure, when disconnecting the forcer from the condenser what you are doing is increasing the working pressures, both high and low, and as the evaporator begins to freeze, I presume that the working pressure while the forcer is on is empty, which occurs when there is either a refrigerant leak or internal obstruction in filter drier and / or capillary tube.
ADMG2000
hace 6 años

THANK YOU FOR YOUR COMMENT WHAT SHOULD THE IDEA WORK PRESSURE BE IN THIS TYPE OF 2-DOOR FRONT DOOR FURNITURE WITH 1/4 OR 1/3 COMPRESSOR?

Responder
Mimol92
Mimol92
8.033
hace 6 años

For R134a the pressure should be between - 2 in. Vacuum and 2 psi, no matter the size of the compressor, what matters is the temperature you want to get inside the refrigerator, but the ideal is to always load by weight, in the cabinet A technical data sheet of the equipment where the type of refrigerant is printed and between brackets the amount of refrigerant, either in grams or ounces, must be placed on the refrigerator.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis