hello jonito, on the remote control you may have a button that says BLOW if you appear on the display of your control you will realize xq appears as a 4-blade venti. This function does what you mention, the forcer...
Hi friend, the small refrigerator resistances are surface (refrigerator frame) can not consume so much. there is another problem there
hello, and the return? How are you, is it cold? If the refrigerator would have only problems with weather stripping, it should in any case work with a cold return, if it does not cut, it is another song, but...
Hello how are you? recently a client (I am a refrigeration technician) calls me to his house to do maintenance on his minisplits equipment, when I finish I leave the house and I see a dishwasher outside, I was ready...
Hello how are you? well the tests you did were with or without clothes? if they were without clothes there is friction between the drum and the bellows that generates the noise. in that case when putting load (clothes) it...
hello, well by checking this washing machine a little, note that not only has the door swich but also a magnet on the tip of the lid, which incidentally when opening the washing machine during the process stops emitting open...
Hello how are you? Bastate ago I did not enter the forum, I was in other occupations. greetings to all. well let's start as the title says I have this top-loading washing machine that does not spin. what is controlled,...
Hello community, I have the following problem, about a month ago this dishwasher broke the buttons on the lid, then I worked on that interface board, Now I have a problem, that when it finishes loading water it gives pulses...
Hi, I think I found the solution, I tried it for about 7 days and had no problems again. The data logger records efficient work with even thaws. I already upload photos. Tergopoles were missing when I took the photos...
Hello, as the title says, the problem is that a small block of ice is made that does not let the air circulate from the bottom up and logically loses cold below. Tests and control: - clean drainage - hot...
en algun lado deberia tener algun dato. y sino averigua aproximadamente cuanto tiempo tiene la heladera. en ocaciones la etiqueda del compresor esta del otro lado, como escondido mirando el mueble de la heladera. fijate eso. y su podes subir...
hola, conozco el tipo de falla que menciona usted, lamentablemente desde mi experiencia solo queda injertar. le explico: - no hay forma de volver a pegar el serpentín al plástico a no ser que se corte por detrás hasta localizar ...
hola,si son vidriadas de 6 puertas desde mi punto de vista deberia ser 1.5hp. por lo menos. depende tambien el tipo degas que usa.
hola, creo haber encontrado la solucion, la probe aproximadamente 7 dias y no volvio a tener problemas. el data logger registro un trabajo eficiente con deshielos parejos. ya subo fotos. faltaban tergopoles cuando saque las fotos que hacen de encauzadores...
Hola como dice el titulo, el problema es que se hace un pequeño bloque de hielo que no deja circular el aire de abajo hacia arriba y logicamente pierde frio abajo. Pruebas y control : - drenaje limpio - termofusible...
hola, cuando deja de enfriar, pudiste observar si esta bloqueado el evaporador de hielo o esta normal frio pero si hielo? sino revisa los capacitores de la placa, valor de sensores (2.7K a 24Cº) fusible termico debe darte continuidad. revisa...
hola, desde mi punto de vista solamente puede ser que el burlete este malo y hay exceso de escarcha, y eso va chorreando cuando corta. o bien el caño de retorno se escarcha x falta de alguna aislación.
efectivamente es un swich de presión que esta cerca de la resistencia por seguridad solo activa la misma si este esta cerrado (funcionando y con presión) es normal abierto
Hola comunidad, tengo el sieguiente problema, hace un mes aprox este lavavajillas se rompio en la tapa los pulsadores, entonces se trabajo sobre esa placa de interfase, ahora tengo un problema, que cuando termina de cargar agua da pulsos como...
hola, bueno revisando un poco este lavarropas note que no solo tiene el swich de puerta sino tambien un iman en la punta de la tapa, que dicho sea de paso al abrir el lavarropas durante el proceso se detiene...