If the filter you took out was full of oil, I would have swept the capillary tube, since if the filter had oil, possibly the capillary would be in the same condition. If you did not have nitrogen, you would...
Is the commercial refrigerator frozen? The chamber environment should be between -18C to -20ºC approximately. Is the thermostat you installed a commercial type of room or contact? If it is of contact, you must adjust it firmly on the surface...
is solved was the thermal fuse of the winding of the turbine engine. directly change the engine because I can not replace that feature. and also this engine runs constantly when you start the computer, I do not want the...
good morning all I have the following drawback: I called customer to see the air because it does not work: the sequence that does is the following: I plug in and power up indicates the power to the plate by...
Hello, good evening. I would need someone to give me some diagram to connect a stop button and a remote control for a three-phase motor. it turns out that in a restaurant was made a modification and the electrical board...
http://www.mouser.com/ds/2/302/BT131-600-527679.pdf fijate ahi si ves las prestaciones y caracateristicas. El bt131 600 es igual al bt131 y al bt16
Hola buen dia. Generalmente detrass de la heladera esta pegado el diagrama electrico del circuito. Fijate, para ubicar de donde le llega alimentacion a ese forzador. Agregando a las correctas respuestas de los colegas, no olvides revisar que voltaje tiene...
Existe un modelo de valvula de expansion por cada tipo de refrigerante. Y de acuerdo a las prestaciones de cada instalacion es el numero de orificio que debe tener instalado. Va una sola tobera por cada valvula las cuales son...
Si el filtro que sacaste estaba full (lleno) de aceite, yo le hubiera hecho un barrido al tubo capilar, ya que si el filtro tenia aceite, posiblemente el capilar estaría en igual condición. Si no tenias nitrógeno, le hubieras hecho...
la heladera comercial es de congelados? el ambiente de la camara deberá estar entre -18C a -20ºC aproximadamente. el termostato que instalaste es tipo comercial de ambiente o de contacto? si es de contacto, deberás ajustarlo firmemente sobre la superficie...
En una heladera no frost no es necesario realizar descongelamiento. Decis que lo haces cada 15 dias. Porque lo haces?
Hola Jorge, pregunto: que problema tuvo la cámara de congelación? porqué le cambiaste la válvula VET? la regulación de la válvula no se toca. que refrigerante estas usando? recordá que si el refrigerante no es puro (R22) debes cargar en...
Hola Marcela, ruido molesto a la altura del freezer, puede que te esté formando demasiado hielo y llega a tocar las aspas del forzador del freezer, (ojo que no se te estropee el motorcito de este ventilador de freezer) debido...
Hola Freddy. esa heladera tiene placa interfaz al frente con luces roja verde y amarilla y display de temperatura de freezer y conservadora. No te indica ningun error? comentá mas detalles para ayudarte. saludos.
Hola arrodriguez53. imagino que esa falla en la aislacion, forma hielo en la parte externa. Podrias subir foto para ver si se puede hacer algo. en alguna oportunidad, tuve un cliente que tenia heladera con freezer nueva de unos 3...
Fijate. Abri la tapa frontal de unid interior. Saca los filtros y busca el sensor de ambiente. Ponelo en modo frio. Toca el bulbo sensor con los dedos para darle calor. Deberia prender. Quiza el bulbo este sucio con tierra...
Quiza si te das maña lo soldas, pasa que tenes que preparar el sector para no quemar nada, Es un tema . tiene que quedar bien y todo depende de tu habilidad, y la comodidad del sector que te deje...
Amigo. Te paso codigo errores de esa marca[url=/ver-adjunto/aHR0cHM6Ly9jZG4yLnlvcmVwYXJvLmNvbS91cGxvYWRzL2RlZmF1bHQvMDAwNC8wNi9TY3JlZW5zaG90XzIwMTgtMDYtMjktMjMtNTAtNTUtNTU1NjQucG5n][img]/js/ckeditor/plugins/attach/attach_25.png[/img]Screenshot_2018-06-29-23-50-55.png[521.77kb][/url]
Hola lupion, mirá, me tocó 2 veces reparar heladeras whirlpool con ese síntoma. con la diferencia que el motor marchaba normal, pero cuando abria la puerta de la conservadora, comenzaba a prender y apagar todo (titilaba la luz interior y...
Hola a todos. solucionado el problema. cambiè la plaqueta por nueva. Todo funciona OK. la bomba la probé directa y funcionaba bien.