In a closed vessel under saturated vapor pressure, the temperature is the same throughout the sterilization chamber and directly proportional to the pressure, eg for 121 ° C it is 1.1 bar. It is not necessary to put the probe...
En recipiente cerrado a presión de vapor saturado, la temperatura es la misma en toda la cámara de esterilización y directamente proporcional a la presión, por ejp para 121ºC es 1,1 bares. No hace falta meter la sonda dentro del...
Esos agitadores tiene un nº de revoluciones mínimas que permite arrancar al motor, ya que a muy bajas tensión o voltaje el motor no logra vencer la fuerza contraelectromotriz y por tanto arrancar. Tienen un potenciómetro ajustable con destornillador en...
Con los datos aportados no se sabe mucho, primero viene el tamaño o potencia que puede disipar sin reventar , por ejp. Q60, pero no te hace falta, ya que si compras uno del mismo tamaño o mas grande solucionado,...
Hola fijate bien en las soldaduras de los componentes que te faltan, supongo que SMD, puede que nunca los tuviera, ya que la tarjeta es común a varios modelos y traen serigrafiados componentes que no hacen falta según modelo, si...
What servimat says is like that. I installed many of these, they are UPS or Online UPS, the others are OFFLINE, there are some intermediate ones that say that they are always generating voltage synchronized with the network voltage, but...
It is very rare, but I would say that you have a power leak and you are also paying for it, because it goes through the counter. I say that it is rare because the leak is usually of the...
If you have two of those, put them in series. Positive to positive and negative to negative, in the center where the two pos and neg temples are joined together. You will make a capacitor of 500 uF 20 volts....
the piece of the wrist of a glove to scrub the dishes, or anything else that fits you on the wrist, stick a metal spire to which you will have welded a cable, in the middle of this cable you...
Basically they are the same, but for starters they are of worse quality and therefore of smaller size. I explain myself a little better. The starters work for a few seconds and therefore, withstanding the stress much less time, the...
Well it is clear that it is an electrical resistance, it can be from an oven. The power and voltage are usually recorded on the tube near the terminals.
The voltage does not multiply, it is simply that it is generated at 380 or out of the distribution transformers of the electricity company, (more than 400V is currently used), they are 3 phases, 120º out of phase, which together...
I believe that does not exist. Discharges of atmospheric origin cannot be checked because it is not known when or where they fall. Electrostatcas discharges are not checked, they are discharged to the ground, as are parasitic or floating tensions...
Most manufacturers recommend alkalines because they do not release acid or sulfate terminals when they are discharged. Which happened to me already in devices that are used sporadically and are stored for many months. Otherwise it doesn't matter.
Hi, that component is an automatically resettable fuse. It has to give about 0.5 ohm of continuity, but it is wrong. The winding also has to give continuity. You can bypass it to test and see if it is the...
Sorry I haven't seen this before. Haber if I arrive on time. The most frequent fault to this that you comment is on the same card or plate where the motors are connected, there are two 15Kohm resistors, they look...
Walservi is right. The problem is always in the applicator. Some equipment (although it is not frequent) have to program the angle of the applicator, if it was poorly selected, put to the minimum burning, since it concentrates all the...
More information is needed, such as the starting type, if it is a triangle star, it would be 3 contactors. or if it is with electronic starter. Direct with a contactor only and for a power factor of 0.8 would...
No se que pasó con "publicación de manuales", de repente no encuentro el "botón" publicar. Tengo la costumbre de que cuando alguien pide un manual técnico lo subo para que quede accesible para todo el mundo. La idea era hacer...
Yo lo tengo, mañana desde el trabajo te lo cuelgo en el apartado de manuales de electromedicina. Saludos.