Hello, my refrigerator turns on the compressor and in a few minutes it turns off, it is still shining and it warms up too much that it will be the fault regards
Roberto Ru
hace 6 años

Hi Jose, have you checked the thermal elements: relay, thermal and capacitor if you include it?

Responder
Josecevada
hace 6 años

If I have placed Reyar Thermal and Capactor and everything marks well what happens that the refrigerator does not cool and to discard the compressor gas, connect it directly without the elements that turn it on and I start the engine for about 2. O 3 minutes and swim

Responder
Josecevada
hace 6 años

And it suddenly turned off and only resounded but the engine was no longer heard and I touched the compressor and it was very hot
Regards
roberto ru

Responder
Roberto Ru
hace 6 años

Jose checks the starter and work coils with tester or multimeter, as well as not having any of those coils grounded. There are tutorials on youtube on how to do it. But for the data you give, apparently the compressor is damaged. Check and I'm still watching the results.

Responder
Roberto Ru
hace 6 años

Jose checks the starter and work coils with tester or multimeter ***, as well as that any of these coils are not grounded. There are tutorials on youtube on how to do it. But for the data you give, apparently the compressor is damaged. Check and I'm still watching the results.

Responder
Josecevada
hace 6 años

The coils check between the common coil and average work 3 ohms and common and medium start 12 ohms and between work and medium start 15 ohms after checking the coils I connected it directly and it started well and a few minutes went off I just left sumbando and I disconnected but the compressor was very hot and I measured coils all measured the previous ohsm less common and worked low at 1 ohm

Responder
Roberto Ru
hace 6 años

Hi José, try starting the direct compressor again and measure the amperage. If the amperage is high, no doubt the compressor is damaged. Although, once the compressor has been disconnected from the system, a final test can be made to start it directly. And if after a few minutes it works normally, then the system may be clogged. Good luck, and I'm waiting for a comment.

Responder
Josecevada
hace 6 años

Hi Roberto Ru
I already connected it directly and the compressor and it didn't start anymore. He only made a small short in the contact at the time of connecting and the work coil its amperage is 1 ohsm low and from there I no longer start at all
Greetings and thanks for your answers

Responder
Roberto Ru
hace 6 años

The compressor is no longer useful, you must replace it and assess whether it is worth investing in such repair. You're welcome and greetings back.

Responder
Josecevada
hace 6 años

Thank you for your great help of your information.
Regards

Responder
Roberto Ru
hace 6 años

José, how well the information served you is the purpose of the page. Greetings and what technical advice is offered.

Responder
Josecevada
hace 6 años

Thank you very much I thank you
Regards roberto ru

Responder
Fermin 007
Fermin 007
57.307
hace 6 años
hace 6 años
If you connected it directly and it started and stopped, that compressor is no longer useful and will have to be changed, regards
Josecevada
hace 6 años

Ok and the compressor refueling filled with gas and materials would come out a lot of budget
Regards FERMIN 007

Responder
ralesme
ralesme
14
hace 6 años

Good morning I have a nevecon Daewoo FRS-2411iaL they cut the cables that connect the card with the thermal and relay and I can not find the electrical diagram to repair it to see if you can help me I appreciate it

Responder
Fermin 007
Fermin 007
57.307
hace 6 años

If you buy it new, then if it is expensive, plus the material and workmanship, but if the refrigerator is still worth it, well go ahead, regards

Responder
Josecevada
hace 6 años

Ok thank you very much for your alluda greetings Fermin

Responder
Fermin 007
Fermin 007
57.307
hace 6 años

You're welcome, but is it? If it already works, share the solution, regards

Responder
Josecevada
hace 6 años

Okay

Responder
ralesme
ralesme
14
hace 6 años
hace 6 años

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis