Good night the situation is as follows. The washing machine has never been in any workshop I am the only owner and the only time they put his hand was at home (my brother who does not know about repairs of this class) and took the balata that he brings next to the motor armor and in the The top of the straw was released, now that I check it to see if it can be solved, the whip that activates the engine balata was loose at the top (figure 1) and therefore the whisker was loose the part The inner part of the engine (figure 2) I accommodated it in the ballast next to the engine and it was well adjusted (figure 3) and the top part I did not find where it was fastened and I ended up holding it by the spring end that makes the spin cover rise and fall (Figure 4) I do not know if it is the right place because when I lift the lid the bullet is detached from the motor body and when the bass is attached to the same part, it causes me concern because (according to me it should be the other way around) this does not infer Nothing in engine operation. When I start the engine, if the lid is down, it can be heard, but the centrifuge tub does not turn at all and if I lift the lid, it does not turn but the engine stops and I do not understand how it would be possible to turn it again and / or if something hinders the rearrangement of the whip that drives the balata. Thanks good night
IMG_20171123_092439.jpg [2.72MB]
IMG_20171123_093206.jpg [2.48MB]
IMG_20171123_111634.jpg [2.65MB]
IMG_20171123_111832.jpg [2.66MB]
[/Url]
The panel where the control knobs go (figure 1) seen from above and below (figure 2).
The cover of the centrifuge had a bolt that came off and that is where the band of the balata was going, I placed a new bolt and right there I put the band with the correct fit, (figure 3). With the bathing in the new position the movements are correct in terms of the balata, the problem is that with the bullet activated or deactivated the spin of the centrifuge does not rotate when the engine is running, the engine is heard, but nothing is moving the tub (figures 4 and 5)
Now I think the problem lies in the engine or something that links the engine with the rotating tub but I don't know what it could be.
Good night greetings.
[url=/ver-adjunto/aHR0cHM6Ly9jZG4ueW9yZXBhcm8uY29tL3VwbG9hZHMvZGVmYXVsdC8wMDAxLzk5L0lNR18yMDE3MTEyOF8xMTM4MDItODg5NDEuanBn]
IMG_20171128_113802.jpg [3.11MB]
IMG_20171128_114302.jpg [3.12MB]
IMG_20171128_124436.jpg [2.89MB]
IMG_20171128_125940.jpg [2.58MB]
IMG_20171128_130125.jpg [2.32MB]