Pedro Clemente
hace 5 años
hace 5 años
Hi. I want to rewind a three speed motor. I have almost all the data, but I don't know how to determine how many laps to put at each speed in the gear coil, they were all as one when I disarmed the winding. Thank you very much in advance who can help.
apolonio neri vallejo
hace 5 años

Is phase 4, 16 slots?

Responder
Pedro Clemente
hace 5 años

That's right!

Responder
apolonio neri vallejo
hace 5 años
hace 5 años
The primary coil is formed by only one enameled cable and the secondary coil or starter is formed by 3 enameled cables (6 tips in total), in your case if you have the starter coils, count the turns and divide them by 3, for example if they are 360 between 3, 120 laps each, luck and comment
Pedro Clemente
hace 5 años

I already put that solution into practice because it was considered the most logical, but only one speed works, in another it is slow and dramatically heats and in the other it only hums and heats without the blades moving.

Responder
apolonio neri vallejo
hace 5 años

How many laps is the primary school? Is the magneto cable new or recycled? What is the primary and secondary caliber?

Responder
Pedro Clemente
hace 5 años

The coil that has a single wire has 496 turns 32 gauge. The three wire has 466 turns 33 gauge. The cable is new

Responder
apolonio neri vallejo
hace 5 años

Czech fan fm450 winding wire detached in this forum, page 1 (speed connections)

Responder
Pedro Clemente
hace 5 años

Dear Apollonius, I really appreciate your attention. My problem is not with the connections, I have that clear, but thanks, the values of the coils published in the link that you recommended gave me an idea of how to calculate the turns of each one of them. Thank you

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis