Perestal type man fan, smoke

Richard Gargom
hace 6 años
hace 6 años
Hello colleagues, I have a doubt I have a 3 speed man fan red, black, blue and white. continuity check but the blue wire does not have continuity with any other wire yes. It has a 5 microamp capacitor. Connected to two red wires but I also had a cable as a bridge connected directly to the face but I removed it. I changed the hub bushings, clean the coil had an abyss nest. On the axis of the arrow on the part where the plastic is cracked. Problem number one, the connection is not correct. I put the white wire on the line and the others in pereo speed every time I turn it on, it turns well but it starts to smoke as it burns. Does it have a solution?
apolonio neri vallejo
hace 6 años

Made smoke because the connections are not correct.

Responder
Richard Gargom
hace 6 años

Hello, this is comrade, I had it badly connected, so it was delivered to me, but I solved the problem and it is already working at ????

Responder
apolonio neri vallejo
hace 6 años
hace 6 años
Black is 1 speed, white is 2 speed, red is 3 speed, the phase must reach speed control (either dial, letter L or keys), blue is neutral and is connected to the other tip of the power cable, which is marked by 3 stripes, luck and comments.
apolonio neri vallejo
hace 6 años

If the blue does not have continuity, the thermal fuse of the bridge that you removed is blown,.

Responder
Richard Gargom
hace 6 años

It was fine in your comment, friend Apollonius, the fuse was indeed melted but I already solved it and fixed it and it was working at ???? Thank you

Responder
apolonio neri vallejo
hace 6 años

Greetings from Acapulco. Mex.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.94
(16)

Curso Refrigeración Comercial Aplicado a Diagnóstico y Reparación

Ing. Georga Melgarejo
$ 40 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis