hace 6 años
GOOD LATE COMPANIONS AND FRIENDS OF YOREPARO.COM, SOMEONE COULD FACILITATE ME OR EXPLAIN THE DIAGRAM OF THE COILS OF A 3-SPEED PEDESTAL FAN, I HAVE VARIOUS FANS THAT THE COILS ARE ORALIZED BY A PROTECTION I WOULD LIKE TO MAKE THEM WORK EVEN IF IT IS ONLY ONE SPEED. THANK YOU!
apolonio neri vallejo
hace 6 años
hace 6 años
If they are revalued, they are no longer useful because they have lost part of their electromagnetic straightness and it is necessary to rewind, luck and comment.
apolonio neri vallejo
hace 6 años

For example, if you have a phase 4 winding, then you have 4 work coils and 4 starter coils (thinner enameled wire), place 4 wire wires on the left (1 thick or thin) and mark them as P., A, B, C and find your pair between the 4 on the right and mark them as P-1, A -1, B -1, C - 1, in this way you will get

Responder
apolonio neri vallejo
hace 6 años

or checks, if all OK edts join P and A for 1 speed, B and A - 1 for 2 speed and C and B - 1 for 3 speed, C - 1 to one end of the capacitor and P - 1 to the other end of the capacitor and thermal fuse and of this the neutral. , luck and comment.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis