⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Tube TVs

tv sharp 19pr100 I don't get the menu

Televisor SHARP 19PR100

Televisor SHARP 19PR100

rudoy25
hace 5 años
hace 5 años
how are they ? I need you to help me with tv sharp failure does not appear the menu does not appear the volume bar or channels? the problem is that the TV is seen and everything but I remain in only the antenna channels and there is no way to change it to cable xq without menu you can not make the change thanks in advance, hand to all who can help me solve that problem
manolo karvalo
hace 5 años

Hi friend, what is the chassis and at what stage of the TV? have you checked to try to fix the fault

Responder
rudoy25
hace 5 años

thanks x answer on the board this appears (19pr100 ox) xq else else is deleted

Responder
nicomena2015
nicomena2015
9.501
hace 5 años
hace 5 años
Friend: I must comment if you have knowledge in electronic or TRC repairs .... if you have them, you may be missing the abilitation pulse either hor, or vertical so that there will be the menu or the display on the screen. .in this case it is in charge of transistors Q2211 and Q2201 .... the Q2211 receives at its base the pulses hor, from the fli-bak and leaves from its collection to pin22 of lc 2001 ... the Q2201 receives in its base the vertical pulse coming from the vertical lc and exits through its collector to pin23 of lc 2001 ... either of the two pulses q, the lc2001 is missing either pin22 HD ... or pin23 VD ... the on-screen menu ... I should check both transistors and the R2201 of 10kohm and the R221 of 2k2ohm if they are in good condition ... measure if there is 4v voltage on the collectors of Q221 and Q2201 ... or on pins 22 and 23 of lc 2001 .... if this contribution was useful, value and comment .... Cheers!
rudoy25
hace 5 años

ok friend thanks, well no? but it is going on, thanks I am going to Czech and I tell you (in Q2201 4.97v in Q2211 4.35v same in pin 23 4.97vy in pin 22 4.35v) and the R - mentioned are the normal value I don't know if the value from pin 22-23 is fine or high thanks

Responder
nicomena2015
nicomena2015
9.501
hace 5 años

measure in pin16 menu ... deve haver 4,8v .... measure R2202 must be 47kohm ... this R is connected to pin7 of the vertical lc lc501 ... and goes to the base of Q2201 ... I must see if the vertical pulse reaches the base of Q2201 .... check the R2213 must be 22kohm and it is connected to the AFC q, it comes from the R641 of 6k8ohm q, it leaves the pin5 of the fli-bak ... check the value of the R641 and the D641 zener if it is not leaking or short-circuited ... the D641 is a 9.1v zener .... this actually needs to be visualized with an oscilloscope .... when changing the air channels It looks on the screen ... I try the remote c ... ok ...

Responder
rudoy25
hace 5 años

ready hand thank you

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?