measure in pin16 menu ... deve haver 4,8v .... measure R2202 must be 47kohm ... this R is connected to pin7 of the vertical lc lc501 ... and goes to the base of Q2201 ... I must see if the vertical pulse reaches the base of Q2201 .... check the R2213 must be 22kohm and it is connected to the AFC q, it comes from the R641 of 6k8ohm q, it leaves the pin5 of the fli-bak ... check the value of the R641 and the D641 zener if it is not leaking or short-circuited ... the D641 is a 9.1v zener .... this actually needs to be visualized with an oscilloscope .... when changing the air channels It looks on the screen ... I try the remote c ... ok ...