⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Tube TVs

daewoo model dtq 20v1ssn turns on and off

jean carlosdigital
hace 5 años
hace 5 años
greetings friends of the forums thanks for your help days ago solutions a problem with a tv daewoo model dtq 20v1ssn chassis cn-001n the tv was turned off at the time of operation at that time I had the inflated c410 condenser replace it and it worked well I delivered it to the customer and it worked perfectly after a month, it brings it back to me with the same fault but now the condenser that had changed it is fine ... the problem that turns it on lasts about 15 minutes on and goes off and on and on and on again it goes off and turn on .. checking component found c402 totally dry replace it and follow the fault ... I checked voltages and everything is fine ... what do you think?
ratonelect63
ratonelect63
5.308
hace 5 años

usually when an elect. you find it dry and then another ..... they all have the same life time or hs. of work and you will find more in that chassis

Responder
nicomena2015
nicomena2015
9.501
hace 5 años
hace 5 años
hello buddy: if I already change the electrolytic source and output voltage of the fli-bak ... review welds on all the pins of the fli-bak and output voltages of the chopper ... if the prob still persists, see if you have The Q804 board acts in conjunction with the (R814 of 0.82ohm) as an OCP protection ... (over consumption protection) ... when this R814 alters its original value it can turn off the TV erroneously ... change it by another R 0.62ohm x 2w ... or you can try welding a R of (1ohm) in parallel with the R814 and see if the TV does not turn off ... you must measure if the voltage of + b remains stable at 133v .. .as a precaution you should change the (C814 of 100mfx160v) and (C812 of 1000mfx25v) ... there is another one (protection x over voltage) q, it goes out of the tension of the rectified filament x D406 and C411 and attenuated x R451 and R452 which via zener D503 joins the line q, goes to pin 34 x-ray ... if the voltage of the + b does not remain stable it can act this protection ... change the C411 of 10mfx100v ... check all that..ok ... comment ... greetings.
jean carlosdigital
hace 5 años

friend nicomena thank you very much for your advice review the welds of the flay back and others where they were cold ... check the c411 and it was devalued replace it and the tv has not turned off it stays in good working order ... once again thank you colleague

Responder
nicomena2015
nicomena2015
9.501
hace 5 años

Hello colleague: I'm glad that you have repaired the fault on the TV ... congratulations! .. thanks x value my contributions to another opportunity and happy holidays ... greetings!

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis