Good morning colleagues, I have a Samsung TV model SL21A8W with problems of horizontal synchronism, the image moves to the sides, I already changed the eeprom memory, also the jungle and I have verified the diodes that are in the environment of the same and I can not find the cause, please if someone has solved this problem before and can help me. Thanks in advance.
jonny5
jonny5
241
hace 5 años
hace 5 años
greetings would help you upload a photo of the fault
tricom
tricom
7
hace 5 años

When I proceeded to turn on the TV to take a picture of the fault, to my surprise, the fault is no longer there, at this point I do not understand if, the fault was due to some faso contact and was corrected when I took out the diodes around the jungle to check if they had escape, anyway I will continue testing the tv to see if the fault comes back, since I do not feel comfortable delivering it to the client without knowing exactly what is the cause of the failure

Responder
José Luis Carpi
hace 5 años
hace 5 años
Hello tricom, first of all a cordial greeting. I think the TV model is CL21A8W Chassis KS2A (N). If so, the problem is that the horizontal sync pulses are not reaching the integrated IC201 (Pin 13). These pulses come from the TSH Collector through R433 = 6K8-2w; from the junction of C407 and C408. You must test these components in addition to Diode DZ402 = 1N4148 which is going to ground; R206 = 10K; D206 and D205 = RB4410. Do it and comment the results.
tricom
tricom
7
hace 5 años

Hi Jose Luis, despite the failure not to be present at this time, I will verify these components, and leave comments on what I find.
Thanks for your help.
Greetings.

Responder
tricom
tricom
7
hace 5 años

Jose Luis thanks for your help, after reviewing the components suggested by you, I found the fault, the probe was in the resistance R206 = 10k since, it changed its value, again thanks for your help.

Responder
José Luis Carpi
hace 5 años

I'm glad you found the problem. Do not forget to like the help. A hug

Responder
tricom
tricom
7
hace 5 años

Thank you Luis, unfortunately my profile is very new and I don't have permission to like. A hug for you too.