If, when raising the R that feeds the vertical IC, the TV remains on. The problem is directed to the vertical stage.
Verify the good condition of all the components (R, C, D, L, etc.) of polarization of the vertical IC.
Change said IC
If the problem persists ... Try temporarily removing Q16 from the circuit. Comment results.
That test is already known friend we are trying to deduce which of the protections is being activated
At what time, was that test done, my dear?
If there is no response in this regard, from the consultant ..
"vertical black stripe on the top ...."
Vertical is from top to bottom, it gives me the impression, which meant horizontal.
If you have a horizontal strip (from left to right) at the top, it means that some component in the vertical stage is still failing. If everything is thoroughly checked, then enter the service menu and reset the vertical amplitude parameters
Hello friend, I recommend you; I did the test that the R423 told me on the board but it does not carry the R
2) The second test cn D303 is demolished on one side and there is no fault
3) And I don't find D401 I just find DZ401
CHANGE THE Q16 and C415 and follow the fault
Then change everything that is around the vertical Ic and dl flayba the capacitors and it goes very well but it enters a thin vertical black line in the part arriva
Carefully measure the resistances that control the vertical, a resistance or filter is likely to be devalued that you have not yet changed