⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Tube TVs

LGfs4rk TV color spots on power up

tayaxin
tayaxin
37
hace 5 años
hace 5 años
Hello friends can you help me with this tv apparently your regulator is damaged but I am not sure since I can not check it xk when turning it on it presents a colorful screen but very dim, beforehand thank you colleagues
miguel 86
miguel 86
2.160
hace 5 años
hace 5 años
Hello, do not define your question well, turn it on or not, which regulator speaks that fails, it will not be integrated vertically that it is faulty, measured source voltage and vertically, I could upload photo of the fault, greetings
tayaxin
tayaxin
37
hace 5 años

If you turn on but turn it on it only looks like rainbow but the dimmer is the regulator, STRX6556 I can't find its diagram to see where the regulated voltage comes from

Responder
manu gonzalez
hace 5 años
hace 5 años
Hi Tayaxin, you do not define the question well, in tube TVs, if the screen comes out with colors, it is magnetized, the fault could be the demagnetizing coils or as surely as the PTC is a three-legged piece that there is in the power supply
tayaxin
tayaxin
37
hace 5 años

I can not send a photo xk the rainbow is almost not well observed, I do not open completely and check the ptc and it is fine and the coil. in fact it is not enough to turn on 100% or hear anything,

Responder
miguel 86
miguel 86
2.160
hace 5 años

Then controls vertical tension or changes integrated

Responder
tayaxin
tayaxin
37
hace 5 años

Thank you very much Miguel, by chance you don't have the diagram? '

Responder
miguel 86
miguel 86
2.160
hace 5 años

And you tried another integrated one?

Responder
franciscovallarta
hace 5 años
hace 5 años
When requesting information be specific with what you want to correctly contribute the data of the TV as a model and chassis, in this case it provides an incomplete model, I send you a 21-inch TV diagram, if it is bigger, comment it, check what they indicate, integrated vertical, if this integrated is damaged it can cause this fault, in this case lower the screen a little and do not have much time on the TV, since the kinescope can degoy ... greetings. lg_21fu4rlg_21fu4rlg-ls_chassis_mc-059c-sm.pdf [4.09MB]
tayaxin
tayaxin
37
hace 5 años

Thank you very much, friend, I already found the diagram and sorry x the lack of data leaves that Czech and I tell you how this is the LG 29FS4RK CHASSIS-CW62C data thank you friend.

Responder
tayaxin
tayaxin
37
hace 5 años

I already changed it and if I opened good only k in 3 minutes a few stripes appear and it is xk the vertical ic overheats what can I do ??

Responder
Javier Chavez C
hace 5 años
hace 5 años
Being with that defect do not keep the TV on for a long time., Preferably remove the vertical IC from the circuit and check the presence of its working voltage Make sure the good condition of the polarization components and surroundings of the verticala IC in addition to the rectification and filtering components that feed said IC. Change the vertical IC .. Strictly and fully checked the suggestions left on the vertical stage, and the problem persists ....., Change the socket (socket) on the board that connects to the TRC
tayaxin
tayaxin
37
hace 5 años

if on that I am thank you friend in fact the ic is heated. vertical in 2 mins is already overheated along with another small ic near the vertical. If I remove the vertical ic and turn on the TV. I will not have any image ??

Responder
Javier Chavez C
hace 5 años

That's right, the characteristic horizontal stripe will come out, but avoid the possible "breakdown" of the .TRC

Responder
tayaxin
tayaxin
37
hace 5 años

ready friend I already extracted the vertical ic and if the line appears in the middle of the screen, does that indicate if my vertical ic is damaged?

Responder
Javier Chavez C
hace 5 años

There are high probabilities but for safety you must change it, after thorough review of your work components around you, those of your power supply and the yoke

Responder
tayaxin
tayaxin
37
hace 5 años

thanks how can I check the yoke with the multimeter, I already have the ic. vertical replacement but I'm checking the surroundings, I just need to check the yoke ???

Responder
Javier Chavez C
hace 5 años

The yoke is tested by measuring its impedance (ohmiaje) and that it is not "short."
Approximately it is always over an impedance of 12 ohm

Responder
tayaxin
tayaxin
37
hace 5 años

yes friend the vertical if it was damaged already opened the screen now only presents a few thin lines of the scan. Is it due to even dry filter?

Responder
Javier Chavez C
hace 5 años

Regulate or adjust the SCREEN.

Responder
franciscovallarta
hace 5 años

if it is in the whole screen it is because the screen is not adjusted properly, lower it a little, if it is only in one part if they are filters, especially change the c304 100micros 50v

Responder
tayaxin
tayaxin
37
hace 5 años

thanks friends, Javier Chavez And Francisco opened the image well only after about 3 minutes these lines appear, it is the filtering di ic. vertical because the capacitor 304 -100mf.50v is already changed. I send you the image

Responder
tayaxin
tayaxin
37
hace 5 años
hace 5 años
ready colleagues the solution was to change the vertical ic a c304 and apparently it remains the same with black lines after 3 minutes k were increasing that was x excessive heat in the vertical ic what is a suggestion in a friend I put a Micro fan to the heatsink so keep it below excessive temperature. and the tube is on all day and everything is going well. Or the other option is to put a larger heatsink.
Javier Chavez C
hace 5 años

Congratulations .
Thank you for sharing the solution

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis