In this TV it is fed with 13 vol positive and 13 vol negative are indicated in the outputs of the transformer on pin2 I have 13.46 vol and pin6 12.77vol pin4 -13.48 vol I think that they are the output pulses or vertical input how many vol they measure the other pins I already put the utc 78040
He touches the pins and only moves a little Asia up the line ahh the TV brand is premier aviated me confused with the brand but the other data is correct
In pin3 of the vertical I have -12.5 volts is this normal? and on pin 14 and 15 I have 1.04 volts and I already changed the jungle and I still don't care
If I remove the vertical in the jungle, it measures 0.90 volts, which is almost 1 volt on pins 14 and 15
Thank you, her ... the diagram in the two lines of the vertical pulses would only help me only a and two r of 100 hom .. and the che and are well and those that are close to the verti..the yoke is fine I measured it and it measured me 10 hom..in the verti line .. I already replaced it too
Hi, her ... I tell you, I already repaired the TV. As I still told the TV, I didn't bring the vertical because it was already revised because the R459 is changed because right here in me I repair I could find the diagram and then I noticed that it was of another value I had an R of 180 hom and the one that is used is a R of 1.2 hom I replaced it and then the TV opened normal ... I suspected that R because it was noticed replaced but I noticed another chasi peer and then I used that R 180 hom but in this tv no THANK YOU herm..by giving me your help