Televisor SONY KV-21ME42C

Televisor SONY KV-21ME42C

kyu
kyu
kyu
120
hace 5 años
hace 5 años
Hello colleagues and good night I get this TV SONY KV-21ME42C 4 FLASHES STAN-BY! I measured the voltages of +13 vol and -13 vol and if these voltages are found, change the vertical IC and the problem still persists, change the capacitors and all the resistors and still nothing. From now I ask for your advice and to solve this tv .......... From TV I appreciate your contributions and thank you very much ATTE Marcio
Carlos Quiroga
hace 5 años

Hi, you have to know first if the problem is at the source or elsewhere. To start you have to disconnect the collector from the horizontal transistor and between that place and GND connect a 60W lamp to see if it turns on, then it will look as follows.

Responder
leasmacruz
leasmacruz
1.594
hace 5 años

For four blinks there ain't nothing sure are 4

Responder
leasmacruz
leasmacruz
1.594
hace 5 años

Already aye something indicates vertical failure try to kitarlo and turn it on

Responder
kyu
kyu
kyu
120
hace 5 años

hello thank you very much I found the fault in a zener diode

Responder
leasmacruz
leasmacruz
1.594
hace 5 años

I'm glad friend

Responder
Javier Chavez C
hace 5 años
hace 5 años
If you already changed the vertical and checked its working voltage, in addition to checking the voltage at + B and that it is within its working standard, I would recommend checking the FBT with a flyback tester and then continue if necessary .
kyu
kyu
kyu
120
hace 5 años

if I changed the vertical colleague and all the R and nothing too the fliback but I found a zener alcostado of the micro jungle

Responder
Javier Chavez C
hace 5 años

As a contribution to the forum, indicate the component causing the fault, by its location code on the board (Ex: D120)

Responder
Javier Chavez C
hace 5 años

Do not forget to assess as a solution to whom it may concern, to close the issue.

Responder
leasmacruz
leasmacruz
1.594
hace 5 años
hace 5 años
check this in the sony vertical failure bulletin
kyu
kyu
kyu
120
hace 5 años

Clear! I changed a lot of things but I did not find the fault then I searched and found a 5.6 volt zener diode in the stage of the micro jungle thank you very much

Responder
kyu
kyu
kyu
120
hace 5 años
hace 5 años
Hello and very grateful colleagues .. after many measurements and changes I measured a zener diode next to the micro jungle which was crossed! I changed it and the fault came out .... I greatly appreciate your contributions and thank you, colleagues ... ATTE Marcio