pantera85
hace 5 años
hace 5 años
HELLO FRIENDS OF THE FORUM I HAVE A PROBLEM CONBUN TV SYVERLUX CHASS PH08KX-N35 WHICH ARRIVED TO ME XQ THE PERSON SAID Q WITH A LOW DOWN THE TV I LEFT WITH THE SMALL IMAGE AND THEN I SHUT OFF AND LISTEN TO SOMETHING. WHEN I CHECK IT I SEE Q THE FILTER C466 160v-4.7mf HAD EXPLOITED AND THE R448 OF 22K WAS CARBONIZED AND OPEN REPLACE THE PIECES. BEFORE LIGHTING IT CHECK THE HORIZONTAL TRANSISTOR ALSO THE VERTICAL, OTHER FILTERS, RESISTORS, DIEDES TO THE REDEDOR EVERYTHING IS OK. BUT WHEN LIGHTING UP AND IN THE CAPE OF 10 SECONDS THE FILTER C466 160v-4.7mf OVER HOT IS INCHED AND DAMAGED COULD HELP ME PARTNERS IF SOME OF YOU HAD THIS FAIL IS THANK YOU FROM HEART. YOU ARE GREETED FROM ACA DE VENEZUELA AMIGOS
duqueelectronica
hace 5 años

Check the flybsck and everything close to the TSH ceramic capacitors and if you carry the small protection capacitor of 1KV or more if this match or broken check visually that area

Responder
pantera85
hace 5 años

Thank you, Duqueelectr, I am telling you, you were right in what you told me and thanks to you alle the solution to that little problem. I followed the tracks of those lines and found a 224j-400v semantic capacitor, this one was damaged but it looked intact and this misto was in the line of the positive capacitor that was overheating. I placed one of the 250v- 434j the TV turned on normal. But with lack of width of the horizontal. It would be for the capacitor to place you. Might you help me. Xq needs to open deo and a half on the left and right side equally. I don't know if you understand my friend

Responder
duqueelectronica
hace 5 años

Put a capacitor in parallel of them that are near the TSH d another board and test if the image is normalized

Responder
pantera85
hace 5 años

Thank you friends for helping me and putting your input of experience with this problem I comment. Ise what they suggested I look for the same capacitor that I was wearing but new and the image looks perfectly removed from the lack of width. Thank you friend Duqueelectr for your help and friend Manolo Karvalo
As ago to give you solution that nothing appears

Responder
manolo karvalo
hace 5 años
hace 5 años
Hello Friend. if you found the bad condor 224jx400volt change it to another one that is of the same value and check the others that are there near the tsh. or it is some filter that can be the one of the + b that is dry or it can be another condenser of those that are in series with the tsh. that is doing that image reduction failure. Cheers