Chinese TV chassis ph08k-n35 with vertical strip on the left side

jeisson2016
hace 5 años
hace 5 años
Friends I have a TV that initially brought it to me because it did not turn on, after checking I found the damaged regulator, it was changed and the TV turned on but with a vertical strip on the left side, I already changed + b, 180v and vertical filters but the fault persists + B 115V 5V EEPROM -14.5 +14.6 [img] https://adjuntos.yoreparo.com/imagen_post/0004/52/cfe6f15c2a6f2a7f5a2f5a2a2a2a2a2a2a2a2a2a2a2a5a2a5a2a5a2a2a5a2a5a2a2a2a2a2a2a2a2a2a2a2a2a2a2a2a2a2a2a2a2a2a2a2a2a1a02 img]
RhonnyUAM
RhonnyUAM
1.284
hace 5 años

And there was no channel other than VTV? Maduro may have soaked your TV

Responder
alcides alvarez
hace 5 años

Hahaha, that guy is a corduroy viruz !!! but, I would recommend checking filters close to the flyback friend.

Responder
jeisson2016
hace 5 años

Thanks for the suggestion????????????
The solution was to change the channel and replace the 680pf c450

Responder
nicomena2015
nicomena2015
9.501
hace 5 años
hace 5 años
hello buddy: the hor seems to be overdue, ... maybe the pulse of synchronism from the hor salt may not be well received ... check the C450 of 680pf x 2000v and the C451 q, it is between mass and the C450 ... C451 reduces the amplitude of peak voltage q, leaves from the collector of the tsh ... also check the R467 of 10k ohm and see if it is not open ... measure the zener VD483 and see if it is not leaking or short. ..the pulse of synchronism arrives from this line to pin57 of lc n301 -... these data are taken from the PH08K-N22 chassis ... if there are no chassis coinsidencies you comment it ... greetings !!
jeisson2016
hace 5 años

Thank you for your help, the solution was indeed right for your comment, the c450 cod 681 2kv was in poor condition, I changed it to a good one and the TV started perfectly.
Thanks friend "nicomena" for the help

Responder
RhonnyUAM
RhonnyUAM
1.284
hace 5 años
hace 5 años
Seriously, it looks like it's sideways, have you tried entering service mode and moving the HPOS?
RhonnyUAM
RhonnyUAM
1.284
hace 5 años

You can check the ceramic and polyester capacitors of the horizontal and even changing the Flyback.
Also check the AFC line guiding you by diagram linked to the TSH collector

Responder
jeisson2016
hace 5 años

Sure enough friend, I found the 680pf c450
Thanks for the help

Responder
RhonnyUAM
RhonnyUAM
1.284
hace 5 años

I'm glad, but he gave the solution to another. good day