You already loaded the unlinked source of the flyback and continue with that whistle?
Did you change the primary and output filters?
Check that the bulb and its circuit are working well first.
Because it's weird to turn on the st and a half 125v.
Check that first. Then take a good look at the spotlight and see if the ST has and mode in that state the source output voltages. Do not give PW.
Comment
If you have another option just change it to discard.
Check the good condition of the diodes and small electrolytes in the primary part of the source
Having fully checked the polarization components of the iC in the primary stage including the error amplifier circuit It would be necessary to change the oscillator IC of the source
disconnect focus q. put in the + b ... leave the source empty put the voltmeter on the positive of the C806 and without taking your eyes off the voltmeter plug the tv and see if voltage appears on the C806 ... if it appears see until q, voltage arrives and if it later falls to stand-by. If there is no voltage, disconnect the TV and measure the D802 and D814 in direct and inverse and see if there are some in short or leaking ... if the diodes are well measure q, voltage it has on pin1 and pin3 of lc 801 in the primary of the source ...
The C806 dE 160V / 100UF filter completely dry with a liquid attached to the plate, the c821 was also replaced. When testing the source with a 60watts bulb I have no secondary voltage, I remove the bulb parallel to the c806, the secondary voltages appear, and the TV turns on. Thanks for such an assertive answer. To test this source with a focus on the secondary line + b the focus for the load of how much it would be.
You already gave the solution to colleague Javier Chavez ... I am supposed to. the tv is already working ....