⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Tube TVs

Daewoo 29 "CN-400F chassis, Mod. DTQ-29U1SSF, image failure, turn off

RUBER965
hace 5 años
hace 5 años
Best regards friends, this time there is a Daewood TV, flat screen, Mod. DTQ-29U1SSF, chassis CN-400F, presents image oscillation at the ends of the screen horizontally, while it is working It goes out, I did superficial inspection of plates and components, I observe the C-816 capacitor, 100uf 160v, slightly inflated, it is located almost next to the main capacitor, I have not made voltage measurements, I await your suggestions according to the experience that they have, since I am not very technical in the matter, I am fond of, but if you can possibly guide me with the failure as in other opportunities, thank you in advance.
RUBER965
hace 5 años

The tv is 29 "

Responder
manolo karvalo
hace 5 años

Hello Friend. change that filter that is inflated and comment

Responder
nicomena2015
nicomena2015
9.501
hace 5 años
hace 5 años
hello friend ... as colleague manolo karvalo says change the C816 of 220mfx160v .... and then you see if you no longer have those oscillations at the hor ends, of the screen ... you must measure the tension q, you have in the + b ... that is in the positive of the C816 ... deve haver 133.5v .... greetings!
RUBER965
hace 5 años

Ready friends. Replace the C816 as indicated and the fault fixed, horizontal oscillations are no longer visible or turned off. Highly grateful.