Thanks for answering colleague. I have done this form in some LG. when the LED strips are in series. by MS or by changing the R of the Source in the mosfet. This case is from Samsung and never try. maxime that this source has several outputs to blanking 7 cables, and these trying to determine how many series of led strips it handles. It is very likely that it can also be done but I don't know the parameters to be modified. Sdos
Thanks for answering colleague. I have done this form in some LG. when the LED strips are in series. by MS or by changing the R of the Source in the mosfet. This case is from Samsung and never try. maxime that this source has several outputs to blanking 7 cables, and these trying to determine how many series of led strips it handles. It is very likely that it can also be done but I don't know the parameters to be modified. Sdos
Friend for me the resistances to be modified are the current census; the R9108 and the R9208 (0.09 oh / 2w).
Hello: I think it would be those two and the voltage in the diodes would decrease. In the attached diagram are 9308 and 9408 and it would be to double the R of the Source that are going to mace of the two mosfet. Well, thank you, I try, and I try. Also, I have already received the service manual with the white balance data and I estimate it could also be tested from there once I lower the source. I attach it tomorrow and look to see what you think You could try reducing Gain values.
The same is done in the video you attached, but this is as simple as in LG. I will comment what happened.
Well, thanks Evelio, I think that the solution is already there and I will do the valorization you deserve for your help. I start to modify these Rs and try-
Independent I would like to open a new question in case of modifying by MS or working on the integrated led driver OD1
which lowers the data and is the SLC2013M. Sdos