⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
LCD TVs - LED

philips 32pfl3605 pulsating source I can't find a solution

Televisor Philips 32PFL3605

Televisor Philips 32PFL3605

herplan111
hace 5 años
hace 5 años
Hello I have pulsating the tension in fsq0465r in leg 6 and in vcc replace optos and kia431a and without results help I can not move forward I do not understand the scheme in the sector ac detected in relation to the optocouplers ... thank you very much if someone can guide me
billy58
billy58
2.182
hace 5 años

Hi excuse me what did you have in the main capacitor

Responder
herplan111
hace 5 años

hello I have 300v that rise 1 or 2 volt but in leg 6 of fsq0465r osila between 220v and 280v

Responder
Victor E
Victor E
65.783
hace 5 años
hace 5 años
it is logical that the tension on that pin is not firm, there goes the tension str and if the integrated one is oscillating that tension will vary, what it has to do is if it has secondary voltage at the source, that of st -by (stand by), 5 volts or 3.3 volts
herplan111
hace 5 años

The VCC of the FSQ0465r in leg 3 also oscillates between 8 and 12v, it is like never stop feeding by leg 6 to feed by leg 3 that comes from the winding for feedback, in the secondary the voltage of 5v is barely a few millivolts, the 12v is also stable a little higher in 14v but I have that driver if it varies a lot between 5 and 15v. the TV arrived with a blown pfc (q602) mosfet and the fuse too, I changed the mosfet, the oscillator driver and connected with the serial lamp and turned on and off with a lot of consumption and burned the mosfet q602 again

Responder
Victor E
Victor E
65.783
hace 5 años

Check the traffic that rel mosfet works with. It may be bad or with connection problems.

Responder
herplan111
hace 5 años

the traffic measures me continuity does not seem scorched what I do not understand because I have a pulsating tension in q101 and the plate is disconnected and I do not have the standby voltage at the base of the q101 rises and falls between 3 and 7 volt

Responder
Victor E
Victor E
65.783
hace 5 años

enable q203 for the source to turn on? it has to have 5 volts on R217 for the source to start, that is the on-off voltage

Responder
herplan111
hace 5 años

Of course the issue is that I have the plate unlinked and I have removed the opto pc102 and still had a pulsating tension based on the q101

Responder
Victor E
Victor E
65.783
hace 5 años

Yes, but to test the source alone you must have transistor q203 activated if not, the source does not start and the measured voltages are all unstable.

Responder
herplan111
hace 5 años

then I make a bridge to q203 but when I put the q 601 (the mosfet) flies me and with the series lamp they turn on and off and to the touch the q601 is burned again, which you recommend me to do the bridge but without the q601 to see the rest of the tensions?

Responder
herplan111
hace 5 años

I make a bridge to q220 also because with the drive voltage that oscillates a lot between 5 and 15v

Responder