Good afternoon dear colleagues of the forum and thanks for your attention, I comment that I go to the workshop a samsung UN40FH5303GCFB with the common LED faults open (dark screen without backlight) to replace the LED sayings I find that I connect it to the source and they don't turn on I proceeded to turn them on with an external source and my LEDs turn on but I don't have the diagram of that source to start
Victor E
Victor E
65.783
hace 5 años

Try disconnecting the main from the source and connect it. They should turn on the LEDs if the source and the LEDs are good.

Responder
eduardomorales87
hace 5 años

Hi Victor and I already did it and they don't turn on however when I try them with an external source if they turn on

Responder
Victor E
Victor E
65.783
hace 5 años

The source is misleading, the external source has no protection and the LED driver does, a bad LED and does not turn on, if with an external source.

Responder
eduardomorales87
hace 5 años

The LEDs that were burned and I changed them !! Test one x one and they are all ok

Responder
Victor E
Victor E
65.783
hace 5 años

Did the voltage coming from the main measure on the bl-on pin?

Responder
eduardomorales87
hace 5 años

I'm testing it without connecting the main to turn on lps leds

Responder
Victor E
Victor E
65.783
hace 5 años

perfect, under normal conditions they should turn on. Follow the bl-on line to the circuit that causes the driver source to turn on, some bad component.

Responder
eduardomorales87
hace 5 años

Sorry x not to continue with the subject victor but had some personal problems could you guide me in the bi-on?

Responder
Victor E
Victor E
65.783
hace 5 años

bl-on is the pulse that comes from the main for the LEDs to turn on, in this case it is a bass, that is 0 volts so that they can turn on the LEDs.

Responder
eduardomorales87
hace 5 años

But with the main disconnected to test backlight should this pulse appear the same?

Responder
Victor E
Victor E
65.783
hace 5 años

no friend, without the main one is a low in the ignition circuit so in normal conditions when disconnecting the main the LEDs light up, the LED card has tension, as placed below in proposed solution, so what there are are LEDs burned

Responder
eduardomorales87
hace 5 años

I am going to change the complete strips to test some type of fault since I test them with my tester and the strips work perfectly !! Ah !! I forgot when I connect the source without the main voltage of 109v drops to 90v

Responder
Victor E
Victor E
65.783
hace 5 años

That shows that the driver source works, burned or short LEDs.

Responder
eduardomorales87
hace 5 años

Thank you!!

Responder
Victor E
Victor E
65.783
hace 5 años

I hope I value my contributions once solved.

Responder
eduardomorales87
hace 5 años
hace 5 años
In the LED connector I have (with ground) D + 109v, -51, +51, -52, +53, D- 0vol
Victor E
Victor E
65.783
hace 5 años

that denotes burned leds.