LCD TVs - LED

Hitachi TV burnt led

Charly1979
hace 5 años
hace 5 años
Hello good afternoon friends. I have a Hitachi brand TV Model: cdh-led40smart04 I have two LEDs burned but I don't know well if they are 3 or 6 vol as I could know friends in some easy I have a dijital tester
nicomena2015
nicomena2015
9.501
hace 5 años

colleague: apart from the testers q, listed below you can try to measure it with the digital voltmeter ... you put the selector x diodes you are looking for a led on the strip q, it is in good condition ... then you look for the positive terminal of the led and the terminal negative ... to the negative terminal of the led you connect the black tip and to the positive terminal you connect the red tip ... if it turns on it is 3v ... if it does not turn on it can be 6v ... if there are doubts you try the first leak ... it is very easy to change the LEDs on that led tv ... I just have to be very careful when disassembling the panel ... not flexing ... it can damage ... greetings!

Responder
Charly1979
hace 5 años

Thank you very much colleague

Responder
nicomena2015
nicomena2015
9.501
hace 5 años
hace 5 años
hello friend: here I leave you a very simple tester to test each led one by one .... you only need a voltmeter a continuous current source between 12-25v and an R of 1kohm .... there is also another more complete tester for measure one by one or measure the entire strip .... there are q. assemble it according to the figure ...
Charly1979
hace 5 años

If I'm going to do it on 2 thanks nicomena2015

Responder
Charly1979
hace 5 años

Buddy, how much amperes the source has to be

Responder
nicomena2015
nicomena2015
9.501
hace 5 años

Hello colleague: if you refer to the first tester it can be a source of 500mp ... or also of 300mp ... in the second tester this is connected directly to the electrical network ... but (EYE) ... the tester that , this in the figure is for an electrical network of 110vac ... but if you have a network of 220vac you must change the electrolytic of 10mfx250v x one of 10mfx400v ... and you must change the R of 10kohm x one of 22kohm x 4w. ... and install a 1A fuse between the mains and the entrance to the diode bridge ... comment if you understood what was suggested .... greetings!

Responder
Charly1979
hace 5 años

Yes nicomena thanks colleague
The first is already perfect
I'm missing 2

Responder