⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
LCD TVs - LED

Plasma fault lg 50pb560b

KINTOLOBO2016
hace 5 años
hace 5 años
Hello again. On this occasion I have to repair an LG 50PB560B plasma. The device turns on for about 2 seconds, shows the manufacturer's logo and turns off, being in stand-by. If I try to turn it on again the process is repeated. I have checked voltages and, apparently, I have everything ok. When you try to do the test AUTO-GEN starts the process, it shows the red screen but it turns off again. Any ideas? Thanks in advance.
sanfalla
sanfalla
1.821
hace 5 años
hace 5 años
are you doing well the auto gene bypassing pin 3 and 4 on the logic card ???
KINTOLOBO2016
hace 5 años

Yes.
I already indicated that the auto gene starts, but it doesn't pass from the red screen.
Thank you.

Responder
sanfalla
sanfalla
1.821
hace 5 años

then you have the damaged logic card

Responder
KINTOLOBO2016
hace 5 años

What does the function of t-con?

Responder
sanfalla
sanfalla
1.821
hace 5 años

if that same in the plasma is called logic

Responder
KINTOLOBO2016
hace 5 años

It reaches to show the green color, but at that moment it goes out.
The plate will be repaired, or better replaced.
Thanks and regards.

Responder
sanfalla
sanfalla
1.821
hace 5 años

change my corduroy less headache and get out of that problem fast

Responder
KINTOLOBO2016
hace 5 años

Card changed, but the problem persists.
It is as if increasing the consumption by turning on the screen, the power is cut off.
Turn on, display the LG logo and turn off.
Greetings.

Responder
sanfalla
sanfalla
1.821
hace 5 años

with that detail that you just mentioned that the logo is seen and goes out immediately is that you must clean the solved flexs and connectors on the tcont card and the main ... it does not make sense but it turns out

Responder
KINTOLOBO2016
hace 5 años

In case it helps:
Power supply voltages. (No load) in volts. 220 / 240v AC network voltage
VS-201.3
VA-54.7
M5V-5.17
MON-4.89
AUTO GND-3.94
RLON-4.65
ACON-5.09
17VDET-2.29
VSON-0.67
VSDET-2.75
5.2-5.17
GND-0
17V-16.99
Voltages measured with 1Kohm resistor bridge between 5.2 and M_ON and 5.2 and RL_ON.
I have already cleaned the flex but it does not improve either the image or the disconnection time.
Greetings and thanks.

Responder
sanfalla
sanfalla
1.821
hace 5 años

well the source is good there is no other to try the main

Responder
KINTOLOBO2016
hace 5 años

The question I have is if the fault can be at the source, and only occurs when it is loaded.

Responder
sanfalla
sanfalla
1.821
hace 5 años

all those voltages are correct ... the source is working you tell me that there is an image but it lasts very little with that I discard the cards "YSUS", "ZSUS", "XSUS", and the buffers change the logic card (TCONT ) I do not give more than the main and speakers

Responder
KINTOLOBO2016
hace 5 años
hace 5 años
Fixed !! Replacement of power supply. For some strange reason when working with cargo, it was disconnected. Thank you all.
sanfalla
sanfalla
1.821
hace 5 años

ok, I'm glad you solved