thanks, I have some experience but I am turning on more than in the technical secondary. I am an electronic technician. I still have it. If you look at the drawing that I leave attached you will see that I took some measurements of the icm801. Regarding the operation I will look for your data sheet but any advice you can give me would be very welcome, thank you very much
Well, according to what I was researching, the icm801 is activated with 12 volts or more of what I have in ic vcc which are 8.4? Is this why it doesn't work?
those 8.4 give me as a result of the 13v that pass through the octocoupler that sends that voltage to the circuit configured by the ktd1347 that delivers the voltage ic vcc t for the icm801 and the icp 801s qye which is a tda4863. Could this be the cause of the breakdown or are they normal?