Hi JJredes ... I tell you that by checking the 400V filter I had one of the loose legs and it is slightly bulged ... I have been looking for it and so far the only thing that I have achieved is one of 120uf / 450V and I wanted to know if that serves me in case you don't get the other one .. Once again Thank you ...
The one that is damaged is 120 micro and 400 V ... The one offered to me is 120 micro and 450 V but it is thicker and the legs are also thicker so I did not buy it ... If anyone knows of any place Where can I get it please let me know to buy it ... thanks ... Preferably in Caracas ...
Hi JJredes ... I have first of all to thank you for all your support ... You were definitely 100% correct in your assessment of the fault ... I got an equal one and replaced it for a positive result. The only observation is that the blue LED stopped working ... Now it does not have the lights that were seen before ... I do not know if it burned at the time the filter failed or there is something that does not He is making contact correctly, but he already has a reception and is looking perfectly. Thanks once again.