⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Security systems

dsc pk5500 -plate dsc1832 clock backward

jpcerutti58
hace 5 años
hace 5 años
Good afternoon!!! I have a question to do I have installed a dsc 1832 device 5 mov + 6 magnetic sensors + int siren and external siren with a dsc pk5500l keyboard now I have configured all the zones etc etc and everything well but when configuring day and time I did it correctly but the time is late !!! the day stays even changes but in one night the clock is 3 hours late, I don't understand what it could be, I need help please. Thank you
warneri92
warneri92
286
hace 5 años

and the board stack how much does it mark you?

Responder
jpcerutti58
hace 5 años

I would not know how to tell you, they set my alarm and I started to do that, at the end of the hour, I asked the question to see if I can solve it by myself without calling the technician, since I do not think it is something serious, the battery is changed as in pc motherboards? where is it on the 1832 plate?

Responder
warneri92
warneri92
286
hace 5 años

I saw the plaque to see leave me and I indicate

Responder
jpcerutti58
hace 5 años

but if it were the battery, it catches my attention that it only delays the time and does not deprogram anything else, that I know when one blocks areas or the day is deprogrammed

Responder
warneri92
warneri92
286
hace 5 años
hace 5 años
jpcerutti58
hace 5 años

ahhh well that would be on the keyboard right?

Responder
warneri92
warneri92
286
hace 5 años

on the board!

Responder
jpcerutti58
hace 5 años

eye that is all clabled nothing wireless I don't know if I should see that

Responder
jpcerutti58
hace 5 años

yes yes already identify it on the board and now ??

Responder
warneri92
warneri92
286
hace 5 años

can you post the wiring?

Responder
warneri92
warneri92
286
hace 5 años

If it works because you have doubts about the cables? I only speak of the battery that is on the opposite side!

Responder
jpcerutti58
hace 5 años

I can not but everything works correctly, as I said you can cancel the zones modify the bell the only thing is the time that is late

Responder
jpcerutti58
hace 5 años

even the system does not mark any error or low battery or any other indole

Responder
warneri92
warneri92
286
hace 5 años

to see a new 3 volt battery should you mark 3.3 volts new / if dial 3.1 will no longer work well I explain?

Responder
jpcerutti58
hace 5 años

ahh good !!! I understand now I have to leave later I check. Thank you friend!

Responder
warneri92
warneri92
286
hace 5 años

walk him

Responder
jpcerutti58
hace 5 años

solved, it was the cycles since being imported equipment comes x defect configured with cycles of frequencies of 50 hz instead of 60 you enter a section an option is called and ready! Thanks for your help Warneri92

Responder
warneri92
warneri92
286
hace 5 años

you are welcome friend

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis