hace 5 años
Hi, I have a question, I am installing the alarm and I would like to know about the topic of adding zones, because when I have the rf5132 should I add zones? because on the keyboard I only dial up to 8 (in the option to enable and disable, in * 85555 202) this rf5132 I use it for wireless, but I would like to know if in total I have 16 zones or 8, thanks
redo
redo
7.086
hace 5 años

I do not understand your question, the dsc pc1832 supports up to 32 maximum zones, either wired or wireless

Responder
Laurenza2003
hace 5 años

I would like to know how to handle them, because I added the RF, but the keyboard only marks me 8 zones (in * 85555 202) which is where I activate and deactivate

Responder
alpaseguridad
hace 5 años

In section 202, you enable zones 1 to 8. In 203, 9 to 16, In 204, 17 to 24 and 205, from 25 to 32.

Responder
Laurenza2003
hace 5 años

Thank you very much, alpaseguridad, you have an idea if with the rf5132 I have 32 zones or how many you add (obviously wireless), Thank you

Responder
alpaseguridad
hace 5 años

The Panel can be expanded up to 32 zones, wired, wireless or mixed. The wired, with expanders and wireless with receivers or receiving keyboards. You must take into account the scope of the detectors. We are at your order for any question.
Greetings.

Responder
Laurenza2003
hace 5 años

I have a distance of 12m, the sensor is ws4904, you say it goes? And another thing how is the installer code issue? In need to change it? None inside the house will change anything, thanks

Responder
alpaseguridad
hace 5 años

The manual explains how to check the reception quality of each detector. The codes are at your discretion whether to change them or not.

Responder
Laurenza2003
hace 5 años

Give it, if I don't fuck you, give me a hand with the issue of putting the phone https://www.yoreparo.com/es/seguridad/alarmas/preguntas/6267762/conectar-telefono-a-pc1832
but I also put it here:
-301 Phone number you want me to call you
-303 Second phone number
-320 enter here what I put?
-350 enter 06 and 06
-380 leave on 1, 5 and 6, leave with #
what I need is to sound when the alarm sounds and not when activating each sensor, thanks

Responder
alpaseguridad
hace 5 años

Section 310 - Enter an account number. Anyone.
311 - The same.
320 - Nothing
There is a general misconception. Each sensor is not activated.
It activates, deactivates, triggers, calls, etc. THE ALARM SYSTEM. That you have connected all the detectors or devices you want.
The zones that you want that do not generate you shots during the activation, must be canceled before activating the System. It is understood?.
Greetings.

Responder
alpaseguridad
hace 5 años
hace 5 años
From what I see, as indicated in comments. You already have everything clear and it is getting long. Set SOLUTION ACCEPTED. And we finish it. That does not mean that if you have any other questions do not answer and help. Just open another post and that's it. You think?. Regards: Alberto
Laurenza2003
hace 5 años

Yes, now I can give it to you, Antea was a comment and he wouldn't let me, thanks

Responder

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis