I have no choice but to tell you that you are a teacher Jorge. I did it and instantly I take it. I close the issue as solved. Many thanks. By the way I consult you. Because you put me in another post that connects phase to C and the continuation of it to NC and by catalog says NO. Thank you Jorge!
Regards
Walter
I may have been wrong. My apologies Finally, you will notice right away; since if you connect it backwards (NC instead of NO), it will stay on at the moment, and it will turn off when activating the PGM .. That is, it would be the other way around.
Greetings
Jorge
As is Jorge. For you to stay it was for NO .... Everything worked great for me thanks to your help.
Regards
Walter