Hello friends !! I have a home alarm X28 807 which is left without battery and therefore without code By placing the new battery I could activate and deactivate with the factory codes 1251 - 1254 and then with * * I managed to load the new code of 4 little dogs Until there everything ok The problem is that I have a remote keypad in the garage and when I want to activate or deactivate it with the new code I DO NOT WORK, that is, the new code loads it on the keypad that is in the control panel and is not accepted if I put it on the remote keypad What should be happening? Note If the garage works but with the factory codes but not with the ones loaded by me THANK YOU
diazomar2004
hace 6 años
hace 6 años
in that central the keyboards are with independent codes that is to say that you have to do the same process in the keyboard that you have in the garage
victor_hugo_p
hace 6 años

Hello Omar !! I tried but I didn't get it.
When I did it in the garage I did the same as in the central. activate deactivate and then press asterisk twice to load the new code. It is assumed that when the asterisk is pressed twice, the two red and green lights begin to flash, waiting for the new code that is loaded twice.
As well
Pressing asterisk twice the lights do not blink therefore it is as if the new code does not take me

Responder
diazomar2004
hace 6 años

I'm sure it's like that but let me look for some old machetes that I must have in case of doubts to be sure since it is in parallel with another (I worked it 7 years)

Responder
victor_hugo_p
hace 6 años

I will thank you very much Omar !! A big greeting and thank you very much for your attention !!

Responder
diazomar2004
hace 6 años

I'm sorry to tell you that I can't find the machetes I keep looking for them if I find them I'll pass them on

Responder
victor_hugo_p
hace 6 años

Thank you Omar!

Responder
victor_hugo_p
hace 6 años

Hello Omar !! I make a query. How do I give the seconds I want to deactivate the alarm when entering the property? I have it with sensors of doors or windows apart from the infrared one and as soon as I enter the property when opening the door it starts to sound and I want that at least 15 seconds to deactivate me. Thank you so much

Responder
diazomar2004
hace 6 años

It is central, the input times are fixed and they are given by 2 capacitors that are on the plate, do the following
note that the entrance door sensor is not in an instant zone if so, pass it to the timed zone that if I remember correctly is zone 1
Now, if the sensor is in the timed zone and does not give you time, it is because the input time capacitors were removed, you look at the plate and surely they are not the same, they are 10 micro farades for 16 or 25 volts of insulation

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis