External Siren Bell does not stop ringing!

encholo
hace 6 años
hace 6 años
Hi guys, I was moving my alarm and installed it in the new docmicilio, everything is fine except the external Siren that is of the bell type. The truth is that the power connection is fine but it seems that the anti-sabotage or opening measure removing the screw is bad or failing and makes it sound constantly - the terminals that exist are those of the photo, leaving only the + and the - connected: 1st Probe by joining the orange wires that go to some spiers that, when the screw is attached, join to know that the bell is armed. 2nd probe joining the two anti sabotage screws with one cable + the orange wires together But the bell does not stop ringing, the photo I send is how the cables were originally placed, the two screws that reach the left screw seemed to be put there to connect it with another sensor in parallel. The alarm is very old and the control panel is only remote controlled, in addition to the terminals that the control panel includes, including those of z1 z2 COM P C + C- 12+ 12- I use all but the P that I suppose will be panic, if someone knows how to make the siren look normal working thank you, maybe you just need a resistance or something .- Of course thanks
encholo
hace 6 años

OBS, where I put this "the two screws that reach the left screw seemed to be put there to connect it with another parallel sensor"
I wanted to put the two cables that reach the left screw, it seems that they are connected there to a sensor in series and are the cables of z1 and com "Thank you

Responder
redo
redo
7.086
hace 6 años
hace 6 años
I understand that if you bridge the 2 tamper screws and connect the + -12v power, it will sound? if so, you must put a relay on the + -bell output of the panel, which gives 12v when firing and cut when stopping
andresvazquez11
hace 6 años
hace 6 años
hello good morning, the wires of the photo according to what I understand range from terminals Z1, COM to the siren's ANTI-BOTTOM screw and attached as seen in the photo, if this is so, directly connect a cable to your panel, enter Z1 AND COM, to close the area directly, and check if the siren stops sounding, if so, you have a problem in the wiring, but you can leave it that way because it is actually canceled as shown in the photo regards Andrew
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis