Dear, I just replaced the old failed pc1565 with a new 0km pc1832 board The programming seems to be accepted ok but in spite of defining the zone 1 as timed, loading the access time and everything, it is triggered as a snapshot and the alarm sounds, not just the bell of the keyboard, without giving me time to deactivate. I reset everything to the factory and twice, x if the flies, but not there. I also verified that [014] option [4] was disabled and nothing .... any suggestions ??? Salu2 !!!
redo
redo
7.086
hace 6 años
hace 6 años
On 013 turn off 6 (audible output error) * 8 5555 013 (here turn off 6) # #
Juan F. Ferrer
hace 6 años

Thank you!
I try and comment!

Responder
Juan F. Ferrer
hace 6 años

EXCELLENT!!!!!!!
Thank you so much X YOUR HELP !!!!

Responder
redo
redo
7.086
hace 6 años

I'm glad your case was solved, 1 salu2

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis