Good friends, I am new to alarms but I have knowledge in electronics. Install an alarm dsc using three zone in a trade that has two front doors, the zones used are the following: Zone 1 (Z1 + com) 5k6 resistance in series: Door 1 (must be delayed) Zone 2 (Z2 + com) 5k6 resistance in series: Door 2 (must be delayed) Zone 3 (Z3 + com) 5k6 resistance in series: internal movement sensor (when the alarm is activated nobody is inside the trade) -I need the programming for those three zones, the alarm is unused. -the calls will be made from a fixed line to two mobile numbers (I think the GSM module is not needed?) That's all folks. If you can not refer me to any post !!
redo
redo
7.086
hace 6 años
hace 6 años
timed zones 1 and 2 and instantaneous z3: * 8 5555 001 010103 # # http://yoreparo.com/seguridad/alarmas/preguntas/924774/dsc-585-callador-telf-como-se-programa http://yoreparo.com/seguridad/alarmas/preguntas/121614/programando-una-dsc-instructivo
plastecn
hace 6 años

What is the weather routine for the areas mentioned?

Responder
elnegrojr
elnegrojr
3.234
hace 6 años
hace 6 años
System times are entered in section 005. Example: 005 015 000 020 004 ## (15 sec input1, 0 ​​sec input2, 20 sec output time and 4 minutes siren time) That would be for the zones settings that you + pas or the colleague. If you want to give different gate times to each gate, you must program the zones, as follows: 001 010203 ## There you can enter: 005 015 030 020 004 ## (we changed the 000 from the previous example, by the input time2, in this example, 30 seconds. I hope it works. regards George
plastecn
hace 6 años

Thank you!

Responder
damianledros
hace 6 años
hace 6 años
I do not know if you already have the rest of the programming? This is to give you time to enter and exit. From the magnetic sensor of the entrance door you must count in seconds how long it takes to get to the keyboard and if you have any sensor pir on the way that would be the second entrance. And the output would be the inverse bone of the keyboard to the door, example * 8 5555 input to programming 005 system time step 020 first input, 010 2nd input, 020 output, 003 how long the siren will sound when it is triggered, then it would * 8 5555 020 010 020 003 ##
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis