Refrigerators

My refrigerator Patrick stops working after a week of the fix

Naza pereyra
hace 5 años
hace 5 años
Hello, I wanted to ask about a fault that my refrigerator has the truth that I already repaired it several times ago cleaning filter change all complete so that it looks good but the truth I do not know if I put too much refrigerant is failing something or that because the first days I froze well all after nothing the part of Frost is going well xq control it, but what I saw that left it turned it off and the other Diana I turn on and it goes well and a week fly do the same to me please I need a help to give you a solution at once.
Fermin 007
Fermin 007
57.307
hace 5 años
hace 5 años
I would say that you changed the capillary tube, since an inner layer forms on the walls and the refrigerant does not pass properly, well sometimes if and sometimes not, if you bring a compressor of 1/5 HP, with three meters of .031 in diameter it would fit you, if it were 1/4 HP, with three meters in diameter .036, luck and greetings
lusangor
lusangor
56.366
hace 5 años
hace 5 años
Hi Possibly the capillary is clogging and goes empty, after giving it rest, it works again, until it becomes clogged again, you may have to do a more thorough cleaning of the circuit If you go over refrigerant charging, you notice it because the tube goes down or comes back, it freezes, but that's why it doesn't stop cooling Check with pressure gauge on, if when it stops cooling, it goes empty regards
Naza pereyra
hace 5 años

Hello, it could be that I have to change the capillary because I did a thorough cleaning with 141 after removing all the dirt was like 15 minutes leaving 141

Responder
friovega63
friovega63
11.849
hace 5 años
hace 5 años
Hi Naza, everything indicates a picture perhaps of humidity, this does not always occur at the same temperature, so it can manifest itself at the moment, or even take days to reappear. Do a good sweep with nitrogen, if you have already used the R-141b, after all this it would be best to change all the oil in the compressor, but before loading the new oil and then obviously removing the old one, apply heat to remove a possible stagnant humidity at the bottom of the compressor, to apply such heat you can use a heat station, the heat must be discreet but with sufficient intensity to remove moisture, but at the same time that a lot of heat does not damage the glass insulation or glass, from the terminals or terminals of the compressor itself, because you would irreparably damage the housing. After the heat, put plugs on the discharge and suction pipes, connect a vacuum pump, by the service outlet provided and keep the pump running, until the compressor cools to room temperature, load the new oil and mount or reinstall in place, as soon as possible to the compressor, weld all the pipes, placing a new filter drier, yes or yes, make the entire system empty again and ready to load with refrigerant and fire the old moisture. Luck. S @ lu2 friovega63. Hi Naza, I do not know why from the beginning, you did not comment on this change of compressor, I want you to know that the difference between capacities is somewhat strong and the compensation of the capillary becomes essential, product of the passage of refrigerant through it employing a compressor with a greater cooling capacity, imposes a greater throttle, which when not corrected, the system literally speaks, a bottleneck, which first begins to hover, negative pressures and then as a dive or free fall, enters a vacuum, which can reach -28 or -30 inches of vacuum, causing the evaporator to first defrost as in a humidity box and finally it can end up damaging the compressor itself. To compensate for the capillary and correct with it the difference between powers, luckily it would only be enough to decrease the length of the capillary, cutting it up to about 60 centimeters, which would differ from each other both capacities, taking into account that these are between 1 / 5+ and 1/4 HP. Luckily it is only cut and not increase, because it would be more difficult. The complicated thing would be if in the way the capillary is installed, there are no ways to eliminate that amount of 60 centimeters in its total length would be 600 millimeters, because in that case it would have to be done, placing a new capillary with the same internal measure preferably and achieve compensation through the pressures that can be obtained in the high pressure gauge, once an appendix is placed at the end of the condenser, before the dryer filter, with the capillary previously welded, stretched along its entire length, without making the spiral to pick it up and with its tip or end opposite to the cut and free filter, to allow the air pressure generated by the compressor to escape, during the compensation process. S @ lu2
Naza pereyra
hace 5 años

The engine is 1/4 and the previous one that had burned was 1/5 or 1/5 + influences that

Responder
friovega63
friovega63
11.849
hace 5 años

Hi Naza, please read a new comment in my solution proposal in response to your new question. S @ lu2

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis