hello, I managed after a long time to look for the resistance, the same, and connect it as it was the previous one, and at the time of doing so I had to wait for all the ice that had formed on the interior panel of the cabinet below the frezer to melt , then connect the 2 terminals and connect the refrigerator to the power, but after an hour running the refrigerator normally, I open it and check the inner panel and again began to form a small frost plate which is already warning me that something is wrong since ice never formed down ... what should I check?
Hello, well if the resistance is 220v, carefully test directly outside 1-2 seconds if it works, if it works you have a problem in the defrosting system,
you should start measuring sensors or bimetal and timer or electronic board ..
Open a new question and put the data of the refrigerator so we can help you, good luck!
Hi, thanks, I went to buy it and they don't have the same or a similar one, but they offered me a resistance cable that resembles a common 1.5-meter electric cable, it is white and measures 3 meters, the seller told me to fix it or roll it up. the old resistance with aluminum tape and fulfills the same function.
Do not buy it because sometimes the seller sells what he thinks and would like his opinion on that product, since grateful
Hello, what country are you from? I'm Venezuelan and I don't know that substitute.