Hello, if it is the minimum temperature you can get then regulate the thermostat at an intermediate point between 1 and 3, it can be 1.5.2, or 2.5 and you can get it to make and make the cuts now, if you manage to lower the required temperature, by Welcome thermostat, regards.
Well folks, I can't hit the spot; As I said before I could have a good cold. Now every time I try I get to -22 ° C and the thermostat doesn't cut. I decided to squirt R22 to see if it cut and it didn't. I calculated that it is the thermostat and take it out, the thermostat is a Ranco K54 - L 1819., I proceeded to test it and place it loose in the environment in a freezer no frost along with the temperature probe and it reached -22 ° C and short. The subject that performs the same test on the frezzer that I am repairing and reached 23 ° C and does not cut. I found some information that I put down
Note tecniche: Freezer flia drawer thermostat - Type VS5-K54
Min: With: -11 ± 1.5
Desc: -32 ± 2.2
Max: Desc: -16 ± 1.5
Source Code:
480127127052 (WHIRLPOOL)
It gives me a disconnection of -32 ° C, will it have to come to that? This frezeer reached a max of -27 and having ice return to the compressor, that is, more than that I will not be able to get it out. Can I regulate the thermostat? It has a single screw between the contacts and that is inserted inwards. On that would have to act? How?? I would appreciate guidance since my papers burned
Well, I was looking to propose a solution to close the post but I didn't find the way. I also comment the solution. I decided to change the thermostat by doubts that it is uncalibrated and after doing so the frezzer came to cut with an inetrmediate position on the dial, keeping the temperature between -19 to -22. Thank you all for your help