⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Refrigerators

The timer on my two-door wirpool no frost refrigerator stops

ALCADI61
hace 5 años
hace 5 años
I have knowledge of electronics, my fridge is a two-door wirpool. I still have the problem. Look at this problem, when my fridge goes into defrosting, the resistance comes in, so the bimetallic is closed, the timer keeps working and when the 21 minutes pass the compressor enters but the timer stops, watch the timer is new, something else in freezing I turn off the fridge and the timer starts again, what is the damage this has me crazy, I changed the quit starter I do not know if this has to do with anything, they put another condenser, a new klixson and the PTC relay put another one that did not It's the same, I tried what they took and everything is good. Please help.
NG en linea
NG en linea
9.229
hace 5 años
hace 5 años
Hi. Maybe the timer is not properly installed, see if the numbering of the legs matches the one you removed. . When it enters defrost and the bimetal closes the timer should stop until the bimetal opens again. If the resistance turns on and the timer continues to run, there is a connection error. If you have the electrical diagram check step by step.
ALCADI61
hace 5 años

The timer is the same as the one you remove.

Responder
NG en linea
NG en linea
9.229
hace 5 años

When it stops working check that voltage is coming to the timer

Responder
friovega63
friovega63
11.849
hace 5 años
hace 5 años
Hi ALCADI61, don't you have the electrical diagram? Maybe behind the team have the diagram and upload it to the website, we can help you better. Without the diagram, it is difficult to know, if the operation of the electrical system and defrosting, this is how you comment. There are many combinations of work for the timer, depending on the mode of feeding, to its inner motor that moves its mechanism. So in principle, what you, with reference to the work of the timer, is observing, it might well turn out to be, the normal functioning of that refrigerator. He does not comment if it is because of the problem he had with the relay and the starter kit that changed his equipment, was that he took into account the operation of the timer, or is that something is still not right and from there, they leave Your doubts Comment please. S @ lu2 friovega63.
ALCADI61
hace 5 años

Hello friend, the fridge worked perfect, it all started when I was given to wash it all, I put the hose everywhere including the part of the compressor where the clixzon and the ptz is, when I dried it and turned it on again it began to freeze, there it was When the technicians changed these devices, they left but this continued to freeze and I realized what I have already told you and there I am. The voltage disappears in the timer motor when it freezes and thaws and continues to run.

Responder
friovega63
friovega63
11.849
hace 5 años

And you don't have the electrical diagram? The problem is that this type of timer behavior could be normal, depending on the electrical circuit, hence the interest in the electrical diagram. To value, yes it really works like this or not. S @ lu2.

Responder
ALCADI61
hace 5 años

The electrical diagram behind the refrigerator was damaged by time.

Responder
friovega63
friovega63
11.849
hace 5 años

Please comment on the model of your refrigerator, to search the Internet, to see if the electrical diagram appears.

Responder
ALCADI61
hace 5 años

2WRT17ZKS

Responder
ALCADI61
hace 5 años
hace 5 años
Hello friends, I finally solved the problem, let's start by saying that the timer that had strangely bought a resistor that has inside 5.2k was not resistance but a capacitor, I took the old timer again and gave myself the task of checking it thoroughly, I found two things, the first one that the 5.2K resistor, one of its ends is connected to pin 2 and not to pin 1 as I see in the tutorials and that the main fault was terminal 3 where one of the phases of the tension arrives and connecting one end of the motor coil was dancing or a bad contact, I corrected this and my fridge started working properly. With this configuration my fridge works. Thank you all for being aware
friovega63
friovega63
11.849
hace 5 años

Hi ALCADI61. Good thing you managed to solve the problem. I already commented that all the timers do not work, nor do they feed their inner motor in the same way, even in similar timers, externally, so it is not always known, the review should be done in that sense and then not face consequences. Thanks for the comunication. S @ lu2

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis