⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Refrigerators

Do I have a problem with a Regina fridge with frost frize?

Samuel roja
hace 5 años
hace 5 años
Hello everyone I repair community I am new to the refrigeration branch, I went to check a refrigerator of a customer and when I loaded the refrigerant it never went up to more than 0.8 amps and gives me a pressure down of 30 PSI off and 20 PSI switched on . My question is because the pressure does not lower to less than 5, and the amperage does not go up that I imagine that with the load it has it should rise. I hope you can help me, thanks.
Samuel roja
hace 5 años

Thanks for your help, the compressor is decompressed, it reaches 200 psi of ajuro.

Responder
NG en linea
NG en linea
9.229
hace 5 años
hace 5 años
Hi . That compressor has mechanical problems, it is not pumping. Disconnect it from the lines, put the sevice valve and start it with the manifold (red clock), it should reach 450psi in a few seconds, turn off and it should remain at that pressure, if it does not get there it arrived.
Raibens Ruben
hace 5 años
hace 5 años
20 PSI? it's a lot of pressure
Fermin 007
Fermin 007
57.307
hace 5 años
hace 5 años
Check the compressor, maybe this performance is already lacking.
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.71
(7)

Curso TV OLED y QLED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 29 USD
$ 10 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis