Hello people, I want to know what price this mo49 plus.es gas works for a refrigerator
Fermin 007
Fermin 007
57.307
hace 5 años
hace 5 años
Same as R12 but less (15% more, less) if you already did it with r12 the load, you should not have any problem, but be careful, the mo49 is loaded with an inverted bottle, that is, liquid phase, little by little, luck.
cesar augusto cerna
hace 5 años
hace 5 años
The load pressure is 9.4 psi. You have to load in liquid phase because it is a mixture, you can pass the liquid through a small section of capillary so that it reaches the compressor as steam and does not damage the valves of this.
elektomaq
elektomaq
62.202
hace 5 años
hace 5 años
Hi 5 psi (average) Eye ..... the load is carried out in liquid phase so it must be done by someone qualified given the risks that this entails Cheers
edu soa
hace 5 años
hace 5 años
Hello, between 7 and 8, your refrigerator will be cutting perfectly a little more, and it won't cut anymore
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.64
(11)

Curso Electrónica para Reparación de Placas

Santiago Cediel
$ 29 USD
$ 11 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis