hello buddy good night what kind of coolant do i use and what engine i replace Is it the same power as the previous one?
regards
Marcos www, frionline.net
Hello colleague, use the R134 that brings the refrigerator, the only thing I always use is dupont and this time necton xq had no other, the engine I bought it at a representative of the brand and in the box it says original Electrolux spare, unlike take out a tecumseh and I put a clutch, now I get to - 27.9 in - 5psi
Hello how are you? I calculate that you performed the cleaning of the system and the corresponding vacuum with a pump .... take it to 0 psi and control the slight cold in the return pipe.
regards
If it was obvious that not all those points were taken into account and I do not charge refrigerant if I do not empty, what I did afterwards was to turn off the refrigerator for an hour and then the plug and reached - 28 but it does not cut, then notice that when plugging it in Do the beep and also the test before starting, just start, so I'll see the plate that has to do in this story, then comment what happened
hello ... have you had any other change of forger change for example ... mechanical damper do you have? Notice if it is not locked.
regards
No, it was never touched, forcing works ten, the damper also works, but I will check the plate that is not damaged something, because the sensor works maybe the plate does not take the signal from the sensor
hello it is probable ..... in the part of conservation the temperatures arrive well?
regards
If yes, the temperature reaches ten, what I notice is that it does not cut by cold and neither towards the frost, so I asked for a sensor kid with a plate that comes all together for this model and I change it, the client told me that about six months ago I was in trouble and there I knew that the engine fused xq never cut, then here in the workshop I disconnected every hour so that it does not pass and there I arrive at - 29
hello you should measure the sensors and see their values ..... the other may be screwing the plate, try the change and see if it cuts by temperature, does the thaw ??
regards
And I have seen the whirpool reach - 29, the issue is that it does not cut me in minimum measured the sensor and gave me a value of 4.5ohm at 24 degrees, I really do not know the value of it,
Well I tell you that the whole problem was that the sensors were not in their corresponding value, so when not stopping for cold and resting it cost you performance, change the sensor kit with the plate and it is ten