Hello friends. I am a technician but I have no practical experience in frost free. I need to know the values of the sensors and resistors of this refrigerator. The problem is that it does not cool down. I already measured both defrosting resistors and they have continuity, the only fuse it brings, at room temperature it is open. The forcer works well. The problem is the typical ice blockage, so I want to know if it is a plate, sensor or fuse problem, and I don't know if I'm on my way. Thank you.
lusangor
lusangor
56.366
hace 5 años
hace 5 años
Hello In principle, the problem is the thermal fuse, because if it does not have continuity, the resistance does not work and therefore the ice blockage. Replace it and now results In this link, service manual ... https://docplayer.es/1210073-Manual-de-servicios-service-manual.html Greetings and luck
Gabriel555
hace 5 años

Hi. Thank you very much for the manual ... I was seeing that it says that if the fuse has blown (open or infinite), the cause must be resolved. The question is what can this be or is it common for this to happen in these refrigerators?

Responder
lusangor
lusangor
56.366
hace 5 años

It is difficult to know the reason, the fuse, it is for when the resistance is over temperature, disconnect so that the refrigerator does not burn, it can be the cause of the temperature sensor or simply touched it

Responder
Fermin 007
Fermin 007
57.307
hace 5 años
hace 5 años
The thermal fuse at all times must mark CONTINUITY, change it again and this wrap it in plastic and put it between the coil, so that it is always fresh or at a low temperature, sometimes by the same natural work they are damaged, if it burns again , it is necessary to check the resistance or the defrost sensor that is out of range, if all goes well, with changing the thermal fuse must remain.
Gabriel555
hace 5 años
hace 5 años
Thank you very much for the help. I will choose to change the complete sensor kit so as not to renege, but I remain calmer, which is something that usually happens. If it burns again I will see another question open if I am in trouble. Thank you!
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.84
(25)

Curso Práctico de Reparación y Bobinado de Motores Eléctricos

Héctor Castiñeira
$ 60 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis