Refrigerators

refrigerator no frost has no air flow down.

mongolia
hace 5 años
hace 5 años
It turns out that the refrigerator does not frost, it cools well, the freezer is perfect, but in the food conservative part it does not. so I threw myself to see the compressor that had a correct amperometric consumption, I immediately thought that the serpentine would be blocked by ice, but no, not the duct that brings the cold down, disassemble the dumper but it was fine, I put the thermometer in the cold air outlet in the food conservator and marked me 12 degrees and with very little air, the forcer already works with the correct power, until I notice that when you open a little the freezer in downward airflow increases, and the temperature went to 3 degrees, apparently the forcer would lack air because as soon as I close the freezer door, the temperature in the food conservator rises. I clarify that the button on the door that controls the ignitor's ignition is good, that has no defect. what occurred to me is that the return of air that is in the slot in the front of the freezer could be covered with dirt or ice, because the change is very clear when opening or closing the freezer door, what do you think?
maauri
maauri
26
hace 5 años
hace 5 años
Good evening my friend .. the times that have happened to me I solved it .. leaving the elice well flush with the lid .. and cutting a little bit the plastic covering the elice (the edge that enters the lid) .. covering the ducts that may be cracked or deformed with metal tape
pablo lamas
pablo lamas
2.661
hace 5 años
hace 5 años
Hello, you are correct defrosting the fridge, until you unlock the return ducts, (suction) and then you give more inclination back, at the level that the doors close alone, greetings.
ismer cabarcas
hace 5 años
hace 5 años
Hello, it could be the dictates of the drain that was clogged, there also enters air
LUKI 72
LUKI 72
30
hace 5 años
hace 5 años
hello for all the check you checked ,,, what temperature has the primary evaporator ,, no-frost ,, work -21 to - 25 g average, and also measure the working temperature of (flaper or damper ).. with what temperature it opens and with what saw .. with that you will know if the cold of work reaches the damper. to work, ,, if you do not have the temperature, possible failure ,, lack of gas 134a. or low performance compressor ,,,,, greetings I hope to collaborate ,,,,, comments
mongolia
hace 5 años
hace 5 años
In the end, it was that it was covered with ice, the return, the tray and the discharge duct, everything is defrosted and I am doing well, thanks.
pablo lamas
pablo lamas
2.661
hace 5 años

Ok friend greetings.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis