colleagues I have a question maybe you can help me Yesterday I saw a refri with a clogged capillary. Right now I don't have nitrogen so I installed a service valve in the low pipe and released the capillary from the filter and used coolant, turning it upside down so that more liquid comes out than gas in theory has more pressure. if you open it stopped and get some black oil out of the capillary outlet and felt an airy but very weak, well I thought the obstruction was already released Then I welded all the tubes and emptied and charged gas but the fridge didn't cool I measured pressure and it was fine at first then with a finger I pressed the worm of the valve and it did not come out almost as if there was no gas then I thought that it became clogged again and warmed the filter and released the capillary and in the filter came out a repichazo of refrigerant gas like everything accumulated there My question is, is that just by cleaning the part of the capillary - evaporator and not the part that is high in the condenser? then there was no way to unclog the capillary or with an industrial air compressor that I borrowed from the client
Delfino Ortiz
hace 5 años
hace 5 años
look what you have to do is change the capillary replace the dehydrator sweep the condenser either with nitrogen or with the 141b make a good vacuum and change compressor oil siv for some bowl t want to save on not making the mentioned points I hope you do Everything that I mentioned otherwise in the end isn't going to work well
maralonso
hace 5 años

good morning thanks for your advice but I would like to know if I did wrong to clean only from the return pipe to the evaporator to leave the capillary but without touching the part of the condenser, that does not clean it. Does it affect doing so? you always have to clean both condenser and evaporator or only the part of the capillary if that is where the obstruction is. Thanks in advance

Responder
Delfino Ortiz
hace 5 años

if it is necessary to clean the 2 parts so it is fine but every time the capillary becomes clogged do not hesitate to change the 2 and do a general sweep on my part if I had the capillary capped I did not clean it I always change it and the filter and do general sweep

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis