HELLO...!!! Supposedly they say that my refrigerator is punctured. Cool up and DOWN NO. The symptoms asked me if the radiator heats up the one in the back ..? I told him no. it is cold. They told me it might be punctured. I ask by this means and before so many people who know about the subject. There is the possibility of patching said puncture. (If I had it ..?). I get down in the mood because if they are punctured they tell me that I should buy another one.
Mimol92
Mimol92
8.033
hace 5 años
hace 5 años
Hello friend, if it is punctured and the pipe is embedded (inside the cabinet), you can adapt an external grill, you do not need to buy another refrigerator, you put a grill that will work as a condenser, the size will depend on the capacity of the compressor, depending on whether it is a unit of 1/3, 1/4, 1/5 or 1/6 hp, the technician who does the job should recommend the size of the grill for you to buy, anyway, it is good Verify that it is indeed leakage, because the systomas that you indicate also apply when the motocompressor decompresses and loses performance, the technician you hire must verify that it has indeed leaked by pressurizing the system with nitrogen.
Mimol92
Mimol92
8.033
hace 5 años

I forgot to clarify that the external grill is only valid when the leak has it in the condenser, that is, in the part where the hot gas transits, if it is in the evaporator, there if it is difficult, you have to devalue inside the refrigerator to weld the area.

Responder
Eduardo G. Gomez
hace 5 años

Very kind your predisposition. The (TECHNICAL) came and the only thing he did was to put gas on him, he didn't even change the filter, if it cools but it is a faint cold, he didn't convince me. There are many chantas as in all areas. That's why I'm here finding out. To charge sent do.

Responder
lsetchemendy
hace 5 años
hace 5 años
If the puncture is in the evaporator, a new chamber can be placed inside

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis