Hi Gustavo, I really appreciate the answer.
Do not clarify that leave the refrigerator for about 5 days between long weekend and search for capacitors.
And now I understand why it should not start immediately. But I still have the doubt about why he is doing it, that is, it is the same board that decides to start 15 seconds after restoring power. I imagine that there the problem is the plate ..
when you plug in the unit, the board does a 15-second test, connects the resistor, stops, connects the forcer and a few seconds later the motor compressor starts, that's the sequence it does, greetings.
I advise you to buy a current protector to protect the plate, if you say there are many power outages.
Hello Gustavo,
Yes, in fact it had one, and now I add a voltage stabilizer, Epec delivers 237.
What I did was put a reconnection delay of 2 minutes on the protector to allow the cylinder to have time to decompress.
I have it working at the maximum of cold 4 days ago and everything is going well.