Hello, I have a vertical refrigerator with two doors that freezes the radiator, I changed the filter and cleaned the pipe, I made a good vacuum but it still makes me ice, the fans work well, which can be
omorma
omorma
15.708
hace 5 años

Hello how are you, comment a little more about your refrigerator, family, commercial, brand model type of refrigerant, cold wet no frost etc.

Responder
Mimol92
Mimol92
8.033
hace 5 años
hace 5 años
Good afternoon Nelson, if the honeycomb is filled with ice you should not have problems with the refrigeration system, the problem is in the defrost or defrost system, it may be that you have the electrical resistance burned or that it does not heat enough or that the fuse thermal is open, if the refrigerator is digital you may have damaged temperature sensors, or there is a problem on the electronic board that does not send the signal for defrosting; If the refrigerator is analog, the bimetal may be damaged and does not close when there is accumulated ice, it may also be the timer that is defective and does not activate the defrost cycle.
Nelson33
Nelson33
164
hace 5 años

It is commercial does not carry resistance only a forcer that is working well

Responder
Mimol92
Mimol92
8.033
hace 5 años

Ok, then check that the thermostat is fine, but cut the signal to the compressor will freeze the honeycomb. The problem may be the thermostat that is not cutting.

Responder
omorma
omorma
15.708
hace 5 años
hace 5 años
Hello, how are you? Possible problem: damaged weather strips, loss of air tightness, and outside moisture formation, formation of ice on the evaporator plate, check the correct position of the thermostat bulb.
Nelson33
Nelson33
164
hace 5 años

Hello again, if I thought about it but they are not well, the truth is that it can not be x that my doubt

Responder
willyguillermo
hace 5 años
hace 5 años
Look for the correct refrigerant charge, it may be missing a bit. That the condenser is clean. Does it have a capillary or valve?
Nelson33
Nelson33
164
hace 5 años

Hello again, it has a capillary, I cleaned it with cleaning liquid 141b, I changed the filter too

Responder
Nelson33
Nelson33
164
hace 5 años
hace 5 años
Thank you all for your time, problem solved. regards
Mimol92
Mimol92
8.033
hace 5 años

Hi Nelson, how did you solve the problem?

Responder
Nelson33
Nelson33
164
hace 5 años

Hello, the problem was that the thermostat bulb left where it was located and did not work where it had to work because it was cut and saturated with ice, it is seen that when it was assembled it left its location

Responder
Mimol92
Mimol92
8.033
hace 5 años

Perfect, I'm glad you solved the problem. Regards.

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.93
(14)

Curso Reparación de Equipos de Audio de Alta Fidelidad

Maximiliano Resch
$ 60 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis