⚡ Descuentos en cursos en video - Lleva tu aprendizaje técnico al siguiente nivel y aprovecha precios especiales antes de que termine la oferta. 🔥 Aprovechar oferta ahora 🔥
Refrigerators

Mabe refrigerator does not cool

Jesús Díaz Gonzalez
hace 5 años
hace 5 años
Good morning I bother again, my refrigerator Mabe Mod. RM99W04LO 18 feet still with the same problem, it does not cool down good only for times now it lasts longer (30 days) after defrosting it already tilts Asia back as they told me but it is still freezing in the drain hole and therefore everything is frozen and I have changed the bimetal, the timer and the original resistance, what would happen if I put two resistors or what else could it be so that the drain does not freeze ??? When it cools it perfectly ASE but once it starts to freeze it breaks the joy it gives me, it helps desperately because there are already the strong heats a thousand thanks in advance for your help Chuy art
Mimol92
Mimol92
8.033
hace 5 años
hace 5 años
Good afternoon, I recommend blowing the drain pipe with pressure, over the years it tends to become clogged with dirt and generates problems of this type; defrost the entire refrigerator and after a few hours you blow the drain pipe with pressure, once you notice that it is free you must pour water into the hole under the honeycomb of the freezer and that water should flow out of the other end of the hose to the drainage basin that is located at the bottom of the refrigerator, make sure that this water is not emptied there under the freezer.
Jesús Díaz Gonzalez
hace 5 años

Ok I will do it then I confirm result thanks

Responder
Gamu88
Gamu88
27
hace 5 años
hace 5 años
What a friend to open if this is of any use to you. You have to see if only the bottom of the freezer where the drain pipe is frozen, you have to make sure that water is not thrown out of a bag that you put in to make it ice and if the whole freezer freezes you will have a problem in timer or defrosting tablet although you have changed it again it usually happens that they leave factory defective because 30 days is a long time so that they present the fault normally in 15 to 20 days it is already destroyed again
Jesús Díaz Gonzalez
hace 5 años

Ok thanks problem solved with a piece of wire inserted into the drain hole and connected from the resistor

Responder
Gamu88
Gamu88
27
hace 5 años

OK luck

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.73
(22)

Curso Reparación de Fuentes Conmutadas de PC y Equipos Electrónicos

Maximiliano Resch
$ 40 USD
$ 20 USD
4.87
(15)

Curso Diseño de Amplificadores de Máxima Fidelidad

Maximiliano Resch
$ 29 USD
$ 13 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis