Durex r12 refrigerator

Cristhian Coronel
hace 5 años
hace 5 años
Good afternoon my question is I have a fridge that was originally r12 they changed the filter and put 406 as a replacement now I have to load it but there is no 406 you can load it with 409 but the refigerator has some gas I can mix those two gases or I have to make it empty law thanks
davidefrainrod
hace 5 años
hace 5 años
Hi Christian, 406 is a substitute for R12 just like 409. And R409 is equal to YH12. I use yh12 and it gives me very good results and the advantage of these substitute gases like the ones I mentioned with respect to r134 is that you don't have to change oil. There are many opinions regarding mixing gases, some say yes, others say that not then if it has very, very little original gas, you can throw 409 but it does not mean that it will break something but it may not yield the equipment as expected . If you do not have a vacuum pump or it is complicated to transfer it to the client's house, then take out the 406 almost to the limit of the minimum pressure inside the pipe and pour 409, and remember to throw it in liquid phase or with an inverted carafe. With the engine off it is ideal, but you need a balance and if you are going to start it with the engine on, add it slowly and slowly until the charge is complete, so that the compressor does not breathe in a liquid state and the piston valves or anything breaks. good luck greetings and value the answers
Christian Peralta
hace 5 años

I also had my doubts because here we no longer see teams of r22, 12, 410 or 134. Thanks for the data, it suits me and I find a gas of those.

Responder
Cristhian Coronel
hace 5 años

Thank you very much, colleague, the information helped me a lot

Responder
Christian Peralta
hace 5 años
hace 5 años
Hello! The equipment that uses r12 can be changed for 134a without problems and is a very common refrigerant, but you should not mix refrigerants because it changes its chemical composition and its properties change.
Cristhian Coronel
hace 5 años

Thanks for the info

Responder
Reparaciones similares solucionadas

¿Conoces una solución?

¡Aprende a reparar con estos cursos YoReparo!

4.25
(8)

Reparación de Placa Main TV LED con el Ing. Picerno

Ing. Alberto H. Picerno
$ 40 USD
$ 20 USD
4.6
(10)

Curso Localización de Fallas en Refrigeración en Heladeras/Neveras On/Off

Yamil Alarcón
$ 29 USD
$ 12 USD
4.64
(45)

Curso Tecnología Inverter - Fabricación de probadores y herramientas

Yamil Alarcón
$ 240 USD
$ 40 USD
¿Tienes una mejor respuesta a este tema? ¿Quieres hacerle una pregunta a nuestra comunidad y sus expertos?
Regístrate gratis